Cleanup
15. Open prime valve and allow flushing
fluid to circulate for 20 seconds to clean
drain tube.
NOTICE
DO NOT run pump without fluid flow.
Damage to packings can occur.
16. Raise siphon tube above flushing fluid
and run striper for 15 to 30 seconds to
drain fluid.
17. Switch ON/OFF switch to OFF. Power
button is NOT illuminated when OFF.
26
If flushing with water, do not leave water in
striper for extended periods. Flush again
with Pump Armor and leave protective
coating in the striper to prevent freezing or
corrosion and to increase striper life.
ti30118a
18. Close prime valve. Trigger gun into
flushing pail to purge fluid from hose.
Open prime valve.
19. Install filter into filter bowl. Make sure