Replacement
procedures
Replacing the feed module
or feed module tires
Releasing the feed module
60
This section provides procedures for replacing the following parts. Use the list
below as a guideline for frequency of replacement.
IMPORTANT:Power down the scanner before opening the scanner to
replace parts.
•
Feed module tires and separation roller tires — tire life will vary
depending upon paper types, environment and cleanliness. Nominal tire
life is approximately 500,000 documents; results will vary. Degradation of
feeder performance, multiple feeds, stoppages, etc. indicate a need to
change tires. Change all of the tires on the feed module and separation
roller at the same time.
•
Feed module and separation roller — it is recommended that you install
a new feed module and separation roller every 4th tire change. Install a
new feed module and separation roller at the same time.
•
Pre-separation pad — it is recommended that you change the pre-
separation pad at least as often as you change the feed module/separation
roller tires.
•
Imaging guides — replace when the imaging guides are heavily
scratched and defects show in the image.
There are two methods of releasing the feed module.
Method 1:
•
Press the release tab to the right to release the feed module from the
scanner.
A-61837 September 2016