Specifications Of Standard Wiring Components; To Connect The Electrical Wiring To The Outdoor Unit - Daikin RXTJ30A2V1B Installer's Reference Manual

Table of Contents

Advertisement

9
|
Electrical installation

9.1.3 Specifications of standard wiring components

9.2 To connect the electrical wiring to the outdoor unit

Installer reference guide
48
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Component
Power supply cable
Interconnection cable
(indoor↔outdoor)
Recommended circuit breaker
Earth leakage circuit breaker / residual current
circuit breaker
1 Remove the service cover. See
2 Strip insulation (20 mm) from the wires.
a
a Strip wire end to this point
b An excessive strip length may cause electrical shock or leakage
3 Open the wire clamp.
4 Connect the interconnection cable and power supply as follows:
1-3
Voltage
Current
Phase
Frequency
Wire sizes
Voltage
Wire size
"6.2.2 To open the outdoor
b
220~240 V
RXTM30: 14.72 A
RXTM40: 15.05 A
RXTJ: 14.66 A
RXTA: 14.83 A
RXTP: 14.88 A
1~
50 Hz
MUST comply with national
wiring regulation
3-core cable
Wire size based on the current,
but not less than 2.5 mm
220~240 V
Only use harmonised wire
providing double insulation and
suitable for applicable voltage
4-core cable
Minimum 0.75 mm
16 A
MUST comply with national
wiring regulation
4
unit" [
 28].
RXTJ-A_RXTA-C_RXTM-A_RXTP-A
4P728168-1 – 2023.03
2
2
R32 split series