GW Instek ASD Series User Manual
GW Instek ASD Series User Manual

GW Instek ASD Series User Manual

Programmable ac power supply
Hide thumbs Also See for ASD Series:
Table of Contents

Advertisement

Quick Links

Programmable AC Power Supply
ASD-1300
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GW Instek ASD Series

  • Page 1 Programmable AC Power Supply ASD-1300 USER MANUAL ISO-9001 CERTIFIED MANUFACTURER...
  • Page 2 This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any time without notice.
  • Page 3: Table Of Contents

    SAFETY INSTRUCTIONS Table of Contents SAFETY INSTRUCTIONS ..........5 GETTING STARTED ............9 Main Features ............10 Appearance .............. 12 INSTALLATION .............. 15 Preparation for Use ..........16 Requirements of Input Power ........16 Input Connection ............. 17 Output Connection ..........19 Power on ..............
  • Page 4 ASD-1300 User Manual REMOTE OPERAION ............70 Set GPIB address and RS-232 Parameters ....71 Programming ............73 Command List ............76 Command for Remote Control ......... 78 APPENDIX ..............106 Protection .............. 107 Specifications ............109 Certificate Of Compliance ........112 TTL Pin Assignment ..........
  • Page 5: Safety Instructions

    SAFETY INSTRUCTIONS AFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to insure your safety and to keep the instrument in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the instrument.
  • Page 6 ASD-1300 User Manual Safety Guidelines Do not place any heavy object on the ASD-1300. General  Guideline Avoid severe impact or rough handling that  leads to damaging the ASD-1300. CAUTION Do not discharge static electricity to the ASD-  1300.
  • Page 7 SAFETY INSTRUCTIONS Location: Indoor, no direct sunlight, dust free,  Operation almost non-conductive pollution (Note below) Environment Relative Humidity: 20%~ 85% (no  condensation) Altitude: < 2000m  Temperature: 0°C to 50°C  (Pollution Degree) EN61010-1:2010 and EN61010-2-030 specifies the pollution degrees and their requirements as follows. The ASD- 1300 falls under degree 2.
  • Page 8 ASD-1300 User Manual Power cord for the United Kingdom When using the power supply in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow:...
  • Page 9: Getting Started

    GW Instek ASD-1300 programmable AC/DC Power Source. In this manual the term, AC/DC Source, stands for GW Instek ASD-1300 programmable AC/DC Source. The AC source is a high efficiency programmable AC power source, which provides low distortion sinusoid AC voltage output and measurement.
  • Page 10: Main Features

    ASD-1300 User Manual Main Features Local operation from the front panel keypad.  Configuration Protection against Over-power, Over-load,  Over-temperature and Fan-fail. Fan speed controlled by output power.  Built-in isolation output relays.  Remote operation via GPIB or RS-232C ...
  • Page 11: Accessories

    GETTING STARTED Accessories Please check the following accessories are included and not damaged during shipment. If there are damaged or shortage of the accessories, please contact GW Instek electronics or sales agent for help. Standard Accessories Part number Description Qty.
  • Page 12: Appearance

    ASD-1300 User Manual Appearance Front Panel Menu/ Home SAVE RECALL Page up Page down ESC/ Enter Cancel Unlock TRIGGER POWER Item Symbol Description LCD panel, display setting and measurement results. LED indicator: OUT(green)indicates AC source normal output  Trigger TRIGGER(yellow)indicates LIST, PULSE, STEP ...
  • Page 13 GETTING STARTED At main menu page, press this key to enter Menu/ “advanced parameter setting” page; at other pages, Home press this key to return to main menu. Short press: Cursor move upward or downward. SAVE Long press: long press at “main menu” “advanced parameters setting menu”...
  • Page 14: Rear Panel

    ASD-1300 User Manual Rear Panel OUTPUT INPUT AC1-150V~/AC2-300V~ Max Power 3000W AC220-240V~ SERIAL NO. MODEL REVISION AND BARCODE LABEL Item Name Description TTL I/O port The 9-pin, D-type female connector conveys TTL signals (AC_ ON, FAULT_OUT and REMOTE_INHIBIT) Output connector Output connector. Outputs power to the loading device.
  • Page 15: Installation

    If any damage is found, please file a claim against the carrier immediately. Do not return the instrument to the factory without obtaining the prior RMA acceptance from GW Instek. Preparation for Use ..........16 Requirements of Input Power ........16 Rating ....................
  • Page 16: Preparation For Use

    ASD-1300 User Manual Preparation for Use Before start using, the instrument must be connected with an appropriate AC line input. As the instrument is cooled by fans, it must be installed in an area with sufficient space for air circulation. It should be used in an area where the environment temperature does not exceed 40°C.
  • Page 17: Input Connection

    INSTALLATION Input Connection The input terminal block is located on the instrument rear panel. The temperature rating of the power cord must be rated at least for 85°C. The current rating of input power line must be greater than or equal to the maximum current rating of the AC source. To put a 30A breaker (ABT A) (30A breaker (ABT B)) at AC input side.
  • Page 18 ASD-1300 User Manual 100-240Vac input terminal To protect operators the wire connected to the GND Caution terminal must be connected to the ground. Under no circumstances shall this AC source be operated without an adequate ground connection. Installation of the AC input power cord must be done by professional personnel in accordance with local electrical codes.
  • Page 19: Output Connection

    INSTALLATION Output Connection The output terminal block is located at the rear of the AC source. Load connecting to the “N” and “L” is done at the output terminals. To meet the safety requirements, the safety cover must be fastened. The wires to the load must be sufficiently large gauges, so they will not overheat while carrying the output current.
  • Page 20: Power On

    ASD-1300 User Manual Power on Before turning on the instrument, all protective earth Caution terminals, extension cords and devices connected to the instrument must be connected to a protective ground. Any interruption of the protective grounding will cause a potential shock hazard that might injure people.
  • Page 21 INSTALLATION Error messages will show on the LCD panel if error Caution occurs during turn on process. Please refer to page 107 for error code. Digital circuit inside AC source may not operate properly if turn on AC source immediately after turn off.
  • Page 22 ASD-1300 User Manual OCAL OERATION The AC source can be configured to operate in local or remote mode. The operation in remote mode through GPIB controller or RS-232C will be described in next chapter. This chapter describes the operation in local mode through the keypad on the front panel for data entry and test.
  • Page 23: Local Oeration

    LOCAL OERATION Inhibit Output by Remote Control Signal (Remote Inhibit) ..46 Power On State ................. 48...
  • Page 24: Operation Through Keypad And Knob

    ASD-1300 User Manual Operation through Keypad and Knob LCD panel will show the self-test message as below after AC switch is on. Then will enter main menu setting page as below. Operator can set output voltage and frequency for three phase. ASD-1300 provides a user-friendly programming interface by using the keypad on the front panel.
  • Page 25 LOCAL OERATION Press Enter key to enter individual parameter  setting menu. After entering individual setting menu, press   Up arrow or  Down arrow key to move cursor to item which wants to modify. Use numerical key or knob to do the ...
  • Page 26: Menu Tree

    ASD-1300 User Manual Menu Tree Main Menu Advanced parameter setting menu 1. SETUP 2. CONFIG 3. LIST 4. PULSE 5. STEP 6. SYNTHESIS Degree On Wave A Count Count Count Synthesis Waveform Degree Off Wave A CSIN CF List Degree Pulse V Step Vac, DV GAIN...
  • Page 27: Main Menu Setting

    LOCAL OERATION Main Menu Setting After the AC source is on and initialization is finished, screen will show the main menu. Default output voltage and frequency is 110V and 60Hz. Voltage and frequency setting are shown on the left side of the screen, the right side of the screen shows the measurement value, example shown as below.
  • Page 28 ASD-1300 User Manual Ipeak/Irms. VA: Apparent power, calculation equation is  Vrms x Irms. VAR: Reactive power. Calculation equation is  √VA...
  • Page 29: Advanced Parameter Setting Menu

    LOCAL OERATION Advanced Parameter Setting Menu Press Menu/ Home key at main menu to enter Operation step  advanced parameter setting menu. User can select an item from item 1~6, then  press Enter key to enter individual setting menu; or press Menu/ Home key to return main menu.
  • Page 30: Setup Function

    ASD-1300 User Manual SETUP Function Operation step 1. Press numerical key  on the front panel to select SETUP option when the advanced parameter setting menu appears. 2. Press Enter key to enter SETUP setting menu shown as figure below. 3.
  • Page 31: Definitions For All Parameters On Setup Setting Menu

    LOCAL OERATION Definitions for all parameters on SETUP setting menu Setting Range Parameter Definition Unit 150.0/ Maximum voltage setting V Limit 300.0 for all pages Maximum output Irms 32.0/ 16.0 A I Limit Delay time for over current OCP Delay protection Voltage Level Output voltage range 150 V/ 300 V...
  • Page 32: Voltage Level Setting

    ASD-1300 User Manual Voltage Level Setting ASD-1300 provides two output voltage levels used for low voltage and high voltage applications. At 300V level, AC source can provide 16.0A in total;At 150V level 32.0A in total can be provided, maximum output power is 3000VA. When switched from 300V to 150V level, AC source will check all voltage settings, and change the setting to 150V if any voltage setting checked is higher than 150V.
  • Page 33: Voltage Sense

    LOCAL OERATION Voltage Sense Voltage Sense determines output voltage measurement point is at AC output terminal (Vout) or input terminal at product under testing (Vsense). If it is set at Vsense, Remote Sense wire must be connected first, otherwise compensate error will occur. AC source will compensate the voltage drop of the output cable if Vsense is selected.
  • Page 34: Buzzer

    ASD-1300 User Manual 2. Rotate knob to change A to B, then press Enter key to confirm setting. Press OUT key when main menu appears, only A Note or B can be selected. If using LIST function, then A or B waveform can be output alternatively. Buzzer When user press numerical key or rotate knob, there is sound from buzzer to confirm the operation, it can be muted if the confirmation...
  • Page 35: Disable (Lock) The Keys At Front Panel

    LOCAL OERATION Disable (Lock) the Keys at Front Panel ASD-1300 allows the user to lock the parameters at front panel to avoid being changed accidently. After the parameters are locked, only Menu/ Home key and OUT key are enabled. Menu/ Home key allows user to return to SETUP menu to enable or disable lock.
  • Page 36: I Limit, Ocp Delay

    ASD-1300 User Manual Operation step 1. Press  Up arrow or  Down arrow key to move cursor to V Limit. 2. Change value to 200.0V by numerical key or knob, then press Enter key to confirm setting. I Limit, OCP Delay I Limit represents current limit, it is used to set the maximum output current (rms).
  • Page 37 LOCAL OERATION Current Output Time Set I Limit is to 3A, OCP delay time to 1.5s. Example Operation step 1. Press  Up arrow or  Down arrow key to move cursor to I Limit. 2. Change value to 3A by numerical key or knob. Then press Enter key to confirm setting.
  • Page 38: Degree On, Off

    ASD-1300 User Manual Degree On, Off ASD-1300 can control the start phase angle (Degree On) or stop phase angle (Degree Off) of the output voltage waveform. Range for Degree On is 0.0~359.9, and is 0.0~360.0 for Degree Off. When Degree Off parameter is 0, the output stopped immediately no matter which output status is at.
  • Page 39: Is Start, Is Interval

    LOCAL OERATION Is Start, Is Interval Both the parameter ranges for Is Start and Is Intervals are 0.0~1000.0 msec, these parameters are used for the surge current measurement. Figure shown below indicates the measurement of the surge current starting at Is Start after output enabled, and measurement time is Is Interval.
  • Page 40 ASD-1300 User Manual 3. Press  Up arrow or  Down arrow key to move cursor to Is Interval. 4. Change parameter to 200 by numerical key or knob. Then press Enter key to confirm setting.
  • Page 41: Config Function

    LOCAL OERATION CONFIG Function Operation step 1. Press numerical key  on the front panel to select CONFIG option when the advanced parameter setting menu appears. 2. Press Enter key to enter CONFIG setting menu shown as figure below. 3. Press ► Page down key to enter page 2.
  • Page 42: Definitions For All Parameters On Config Setting Menu

    ASD-1300 User Manual Definitions for all parameters on CONFIG setting menu Setting Range Parameter Definition Minimum Maximum Stored group A waveform Wave A Sin, CSin, DST0 ~ DST31 Stored group B waveform Wave B Address of GPIB GPIB ADDR RS232 Odd/Even parity check NONE, EVEN, ODD RS232 Parity RS232 Baud Rate Baud Rate of RS232 9600/ 19200...
  • Page 43 LOCAL OERATION 2. Rotate Knob to change SIN to DST20. Then press Enter key to confirm setting. The processes to set group B waveform as cut Example sinusoidal waveform (Cut Sine) with CF 1.300. Operation step 1. Press  Up arrow or  Down arrow key to move cursor to Wave B.
  • Page 44: Gpib, Rs232 Communication Setting

    ASD-1300 User Manual GPIB, RS232 Communication Setting ASD-1300 provides remote control operation, there are GPIB or RS232 interface for selection. Only one interface can be activated at the same time. Controller Menu Remote (GPIB) Remote (RS232) (front panel) Operation Mode Menu (front panel) Remote (GPIB) Remote (RS232)
  • Page 45 LOCAL OERATION Set GPIB address to 20 Example Operation step 1. Press  Up arrow or  Down arrow key to move cursor to GPIB ADDR. 2. Change parameter to 20 by using numerical key or knob. Then press Enter key to confirm setting.
  • Page 46 ASD-1300 User Manual 4. Rotate Knob to change parameter from NONE to ODD. Then press Enter key to confirm setting. Inhibit Output by Remote Control Signal (Remote Inhibit) Remote Inhibit is an “Active HIGH” TTL signal, high level is 5V, low level is 0V.
  • Page 47 LOCAL OERATION Output Time TTL signal changes from LOW to HIGH, and stays high longer than 1ms, ASD-1300 resume output. Output Time TRIG: TTL signal changes from HIGH to LOW,  and keeps low longer than 1ms, ASD-1300 turn off output, and stop detecting TTL signal, output stays at off state even TTL signal changes to high.
  • Page 48 ASD-1300 User Manual The processes to change Remote Inhibit setting Example from OFF to TRIG. Operation step 1. Press  Up arrow or  Down arrow key to move cursor to Remote Inhibit. 2. Rotate Knob to change parameter value from OFF to TRIG.
  • Page 49 LOCAL OERATION 4. Press  Up arrow or  Down arrow key to move cursor to Vdc . 5. Change parameter value to 100.0V by using numerical key or knob. Then press Enter key to confirm setting. 6. Press  Up arrow or  Down arrow key to move cursor to F.
  • Page 50: Applicaion

    ASD-1300 User Manual PPLICAION ASD-1300 provides not only stable AC voltage but also three kinds of programmable dynamic output. Following paragraphs explain the definition of parameters and how to do the setting. LIST Mode ............... 51 Definitions for all parameters on LIST setting menu ....52 PULSE Mode ............
  • Page 51: List Mode

    APPLICAION LIST Mode Let user to set 10 sets of user-defined voltage, frequency. This mode can make 10 different outputs consecutively. Operation step 1. Press numerical key  on the front panel to select LIST option when the advanced parameter setting menu appears. 2.
  • Page 52: Definitions For All Parameters On List Setting Menu

    ASD-1300 User Manual Definitions for all parameters on LIST setting menu Setting Range Parameter Definition Min. Max. Execution times for one complete List waveform. When 0 is setting, output 10000 Count recycles endless until user presses Enter key to stop. Start voltage(V): (high voltage range) 300.0 V Start...
  • Page 53 APPLICAION Trigger ON ⁄ OFF is output switch for List waveform, output status is current output status. At this page, there are two modes. 1. To output List waveform Press Enter key to start output List waveform.  Screen will show information as below during output is in process.
  • Page 54 ASD-1300 User Manual programmed in LIST mode. There are two ways to leave Trigger page Under output is off, press ESC/ Cancel key  will return to LIST initialization page. Press Menu/ Home key return to main menu.  Example: Parameter setting Output waveform SEQ - 0...
  • Page 55: Pulse Mode

    APPLICAION PULSE Mode Simulate repeatedly changed output voltage. Operation step 1. Press numerical key  on the front panel to select PULSE option when the advanced parameter setting menu appears. 2. Press Enter key to enter PULSE setting menu shown as figure below. PULSE mode lets user insert fixed period, programmed special waveform to output waveform set at main menu.
  • Page 56 ASD-1300 User Manual Degree On Start phase angle of Pulse output 359.9 Select Go to Trigger Mode, press Enter key to Operation step  do the setting. Screen shows information as below at trigger page. “Trigger On” represents that the trigger is ...
  • Page 57 APPLICAION Example: Parameter setting Output waveform...
  • Page 58: Step Mode

    ASD-1300 User Manual STEP Mode Simulate gradually changed output voltage. Operation step 1. Press numerical key  on the front panel to select STEP option when the advanced parameter setting menu appears. 2. Press Enter key to enter STEP setting menu shown as figure below.
  • Page 59 APPLICAION For each STEP, voltage waveform changes satisfy following equation. + dV  Voltage amplitude of next STEP =current voltage amplitude + STEP amplitude change. + dF  Voltage frequency of next STEP =current voltage frequency + STEP frequency change. Select Go to Trigger Mode, press Enter key to Operation step ...
  • Page 60 ASD-1300 User Manual When the output state of AC source is  triggered, press OUT key can stop the output. Press OUT key again, the AC source will  output the waveform according to the main page setting. Press Enter key, then output state can be ...
  • Page 61: Synthesis Self-Defined Waveform Mode

    APPLICAION SYNTHESIS Self-Defined Waveform Mode ASD-1300 also provides 39 orders of amplitude and phase angle settings for user to make self-defined waveforms. It can be used at all output modes once the self-defined waveforms are created. Operation step 1. Press numerical key  on the front panel to select STEP option when the advanced parameter setting menu appears.
  • Page 62: Definitions For All Parameters On Step Setting Menu

    ASD-1300 User Manual Definitions for all parameters on STEP setting menu Setting Range Parameter Definition Min. Max. Name for two sets of SYNTHESIS DST30/ DST31 Waveform waveform Order 2~20 33.33 Voltage amplitude ratio of Order 21~30 Harmonic to fundamental wave Gain 30.00 for each order.
  • Page 63 APPLICAION SYNTHESIS mode Example of SYNTHESIS mode Output waveform n(w) + 2.07 × (2 + 0.0) + 9.80 × (5 + 0.0) + 15.80 × (7 + 0.0) + 2.16 × (8 + 0.0)
  • Page 64: Save And Recall

    ASD-1300 User Manual AVE AND RECALL ASD-1300 provides two modes for users to save and recall the output setting or the system information. Save and recall the main page setting ...... 65 Save the main page setting .............. 65 Recall the main page setting ............66 Save and recall the system setting ......
  • Page 65: Save And Recall The Main Page Setting

    SAVE AND RECALL Save and recall the main page setting AC power supply provides two modes for users to save and recall the output setting or the system information. Save the main page setting ASD-1300 provides 9 channels for users to save V and F. Users can save or recall the specific parameters at any time.
  • Page 66: Recall The Main Page Setting

    ASD-1300 User Manual Recall the main page setting The process to recall the setting stored in Channel Example 2 Memory (V=150V, F=80Hz) to the main page. Operation step 1. Press  Recall key about 2 seconds in the main page, then it will enter the storage page as shown below.
  • Page 67: Save And Recall The System Setting

    SAVE AND RECALL Save and recall the system setting ASD-1300 provides 3 groups of memory for users to save the system data. System data contains the parameters in SETUP and CONFIG pages. Enter the PAGE SELECT screen, as shown below. Operation step Save the System Setting Operation step...
  • Page 68: Recall The System Setting

    ASD-1300 User Manual Recall the System Setting Operation step 1. Press  Recall key about 2 seconds in PAGE SELECT page, then it will enter the system data recalling mode, as shown below. 2. Choose a group of Group 1 to Group 3. 3.
  • Page 69 SAVE AND RECALL...
  • Page 70: Remote Operaion

    ASD-1300 User Manual EMOTE OPERAION ASD-1300 can be remotely controlled by GPIB or RS-232. GPIB interface is an 8-bit parallel data bus with other control lines to manage communication. RS-232 transmits data in series so communication speed is slower. If transmission speed is faster than data processing speed of micro-processor, micro- processor will neglect new received command when there is command under processing.
  • Page 71: Set Gpib Address And Rs-232 Parameters

    REMOTE OPERAION Set GPIB address and RS-232 Parameters GPIB and RS-232 parameters can be set at CONFIG page. Default address of GPIB is 30, baud rate of RS232 is 9600, and Even/odd parity check of RS232 is NONE. RS-232 pin definition RS-232 interface uses RXD and TXD signals only.
  • Page 72 ASD-1300 User Manual remotely. Press - / Unlock key to switch from remote control back to local control, other keys are inactive during remote control. Screen shows >REMOTE< when AC source is Operation step  in remote control as below...
  • Page 73: Programming

    REMOTE OPERAION Programming All commands and responses are transferred in the form of ASCII code. Response must be received completely before sending a new command. Otherwise, error will occur due to message disorder. Conventions <> Items in angle brackets are abbreviations for Angle bracket parameter.
  • Page 74 ASD-1300 User Manual higher level commands are more close to left side, and the more detailed commands are more close to right side. ASD-1300 includes two distinctive types of command. The first one is command described in IEEE 488.2, it is common commands for GPIB, represented by “*”...
  • Page 75 REMOTE OPERAION VOLT:AC Example 100;:FETCh:CURRent:AC? Explanation The above instruction has two commands which are VOLT:AC 100 and FETCh:CURRent:AC?. Using (;:) can connect commands more than two. Space( ):  Space is used to separate command and number or string after it. Instrument differentiates command and data by space.
  • Page 76: Command List

    ASD-1300 User Manual Command List *ESE ..................78 IEEE 488.2 *ESR ..................79 Standard *IDN ..................79 Commands *RCL ..................79 *SAV ..................80 *SRE ..................80 *STB ..................81 *CLS ..................81 :FETCh:CURRent:AC :MEASure:CURRent:AC .... 82 FETCH and :FETCh:CURRent:AMPLitude:MAXimum MEAURE :MEASure:CURRent:AMPLitude:MAXimum ....
  • Page 77 REMOTE OPERAION [:SOURce]:FUNCtion:SHAPe:B ........91 [:SOURce]:FUNCtion:SHAPe:B:CF ......... 92 [:SOURce]:VOLTage:AC ............ 92 [:SOURce]:VOLTage:LIMit:AC ......... 92 [:SOURce]:VOLTage:RANGe ........... 93 [:SOURce]:VOLTage:SENSe ..........93 [:SOURce]:CONFigure:INHibit ........94 [:SOURce]:PHASe:ON ............94 [:SOURce]:PHASe:OFF ............94 [:SOURce]:LIST:COUNt ............ 95 [:SOURce]:LIST:DWELl ............. 95 [:SOURce]:LIST:SHAPe ............95 [:SOURce]:LIST:VOLTage:AC:STARt ......96 [:SOURce]:LIST:VOLTage:AC:END .......
  • Page 78: Command For Remote Control

    ASD-1300 User Manual Command for Remote Control IEEE 488.2 Standard Commands *ESE ..................78 *ESR ..................79 *IDN ..................79 *RCL ..................79 *SAV ..................80 *SRE ..................80 *STB ..................81 *CLS ..................81 *ESE Query Set and query flag mask for standard event status Description register.
  • Page 79: Esr

    REMOTE OPERAION Power on Syntax *ESE<NR1> Query Syntax *ESE? Parameter/ <NR1> Return parameter *ESR Query Query value stored in standard events status Description register, 1 represents event occurs. Query Syntax *ESR? *IDN Query Return string of AC source identification. Description Query Syntax *IDN? Return parameter <string>...
  • Page 80: Sav

    ASD-1300 User Manual *SAV Save system setting Description Syntax *SAV<NR1> Return parameter 1 *SRE Query Set and return status of flag mask status for Description service events. This command is for a register used for IEE488.2 and instrument defined service events. It is used for flag mask or control enable.
  • Page 81: Stb

    REMOTE OPERAION Syntax *SRE <NR1> Query Syntax *SRE? Parameter/ <NR1> Return parameter *STB Query Query value stored in service event register, 1 Description represents event occurs. Query Syntax *STB? Return parameter <NR1> *CLS Clear status. Following operation may execute Description depends on different conditions.
  • Page 82: Fetch And :Fetch:current:ac :Measure:current:ac

    ASD-1300 User Manual FETCH and MEAURE Commands Differences between FETCH and MEASURE are: FETCH reads existing measurements value. Execution time is shorter because data is available immediately but the data may not be the newest. Instrument will send the next sampling data to the computer after receiving MEASURE command.
  • Page 83: Meaure :Fetch:current:amplitude:maximum Commands :Measure:current:amplitude:maximum

    REMOTE OPERAION :FETCh:CURRent:AMPLitude:MAXimum :MEASure:CURRent:AMPLitude:MAXimum Query Query total output peak current Description Syntax :FETCh:CURRent:AMPLitude:MAXimum? :MEASure:CURRent:AMPLitude:MAXimum? Return Parameter <NR2> :FETCh:CURRent:CREStfactor :MEASure:CURRent:CREStfactor Query Query output current crest factor Description Syntax :FETCh:CURRent:CREStfactor? :MEASure:CURRent:CREStfactor? Return Parameter <NR2> :FETCh:CURRent:INRush :MEASure:CURRent:INRush Query Query output inrush current Description Syntax :FETCh:CURRent:INRush? :MEASure:CURRent:INRush?
  • Page 84: Fetch:power:ac[:Real] :Measure:power:ac[:Real]

    ASD-1300 User Manual :FETCh:POWer:AC[:REAL] :MEASure:POWer:AC[:REAL] Query Query output real power Description Syntax :FETCh:POWer:AC? :MEASure:POWer:AC:REAL? Return Parameter <NR2> :FETCh:POWer:AC:APParent :MEASure:POWer:AC:APParent Query Query output apparent power Description Syntax :FETCh:POWer:AC:APParent? :MEASure:POWer:AC:APParent? Return Parameter <NR2> :FETCh:POWer:AC:PFACtor :MEASure:POWer:AC:PFACtor Query Query output power factor Description Syntax :FETCh:POWer:AC:PFACtor? :MEASure:POWer:AC:PFACtor? Return Parameter <NR2>...
  • Page 85: Fetch:voltage:acdc :Measure:voltage:acdc

    REMOTE OPERAION :FETCh:VOLTage:ACDC :MEASure:VOLTage:ACDC Query Query average output voltage Vrms Description Syntax :FETCh:VOLTage:ACDC?:MEASure:VOLTage:ACDC? Return Parameter <NR2>...
  • Page 86: Output

    ASD-1300 User Manual OUTPUT Commands :OUTPut ................. 86 :OUTPut:MODE ..............86 :OUTPut Query Set or query status of turning on or turning off Description output. Syntax OUTPut Query Syntax OUTPut? Parameter/Return parameter Example OUTPut? OUTPut ON Query output status. Turn on output. :OUTPut:MODE Query Set or query output mode.
  • Page 87 REMOTE OPERAION Example OUTPut:MODE? OUTPut:MODE LIST Query output mode. Set output as LIST mode.
  • Page 88 ASD-1300 User Manual SOURCE Commands [:SOURce]:CURRent:LIMit ..........89 [:SOURce]:CURRent:DELay ..........89 [:SOURce]:CURRent:INRush:STARt ....... 89 [:SOURce]:CURRent:INRush:INTerval ......90 [:SOURce]:FREQuency ............90 [:SOURce]:FUNCtion:SHAPe ..........90 [:SOURce]:FUNCtion:SHAPe:A ........91 [:SOURce]:FUNCtion:SHAPe:A:CF ......... 91 [:SOURce]:FUNCtion:SHAPe:B ........91 [:SOURce]:FUNCtion:SHAPe:B:CF ......... 92 [:SOURce]:VOLTage:AC ............ 92 [:SOURce]:VOLTage:LIMit:AC ......... 92 [:SOURce]:VOLTage:RANGe ...........
  • Page 89: [:Source]:Current:limit

    REMOTE OPERAION [:SOURce]:SYNThesis:PHASe ......... 103 [:SOURce]:CURRent:LIMit Query Set or query total output rms current limit Description Syntax [:SOURce:]CURRent:LIMit Query Syntax [:SOURce:]CURRent:LIMit? Effective rang: Parameter/ <NR2> 0.00 ~ 32.00 (150V range), Return parameter 0.00 ~ 16.00 (300V range) Example [:SOURce:]CURRent:LIMit 25.5 [:SOURce]:CURRent:DELay Query Set or query delay time to trigger software over...
  • Page 90: [:Source]:Current:inrush:interval

    ASD-1300 User Manual Example [:SOURce:]CURRent:INRush:STARt? 200.3 [:SOURce]:CURRent:INRush:INTerval Query Set or query inrush current measurement time. Description Syntax [:SOURce:]CURRent:INRush:INTerval Query Syntax [:SOURce:]CURRent:INRush:INTerval? Effective rang: 0.0 ~ 1000.0 (unit: msec) Parameter/ <NR2> Return parameter Example [:SOURce:]CURRent:INRush:INTerval? 400.8 [:SOURce]:FREQuency Query Set or query frequency of output waveform. Description Syntax [:SOURce:]FREQuency...
  • Page 91: [:Source]:Function:shape:a

    REMOTE OPERAION Example [:SOURce:]FUNCtion:SHAPe? [:SOURce]:FUNCtion:SHAPe:A Query Set or query waveform of waveform buffer A. Description Syntax [:SOURce:]FUNCtion:SHAPe:A Query Syntax [:SOURce:]FUNCtion:SHAPe:A? Parameter/ SINE Return parameter CSIN DST<00~31> Example [:SOURce:]FUNCtion:SHAPe:A? CSIN [:SOURce]:FUNCtion:SHAPe:A:CF Query Set or query CF of the cut sin waveform in Description waveform buffer A.
  • Page 92: [:Source]:Function:shape:b:cf

    ASD-1300 User Manual Parameter/ SINE Return parameter CSIN DST<00~31> Example [:SOURce:]FUNCtion:SHAPe:B? CSIN [:SOURce]:FUNCtion:SHAPe:B:CF Query Set or query CF of the cut sin waveform in Description waveform buffer B. It is effective only when CSIN is selected for waveform buffer B. Syntax [:SOURce:]FUNCtion:SHAPe:B:CF Query Syntax...
  • Page 93: [:Source]:Voltage:range

    REMOTE OPERAION Syntax [:SOURce:]VOLTage:LIMit:AC Query Syntax [:SOURce:]VOLTage:LIMit:AC? Effective range: Parameter/ <NR2> 0.0 ~ 150.0 (low voltage range), Return parameter 0.0 ~ 300.0 (high voltage range) Example [:SOURce:]VOLTage:LIMit:AC? 300.0 [:SOURce]:VOLTage:RANGe Query Set or query output voltage range. Description Voltage range(V) Current range(A) 0.0 ~ 150.0 0.0 ~ 32.0 0.0 ~ 300.0...
  • Page 94: [:Source]:Configure:inhibit

    ASD-1300 User Manual [:SOURce]:CONFigure:INHibit Query Set or query remote TTL inhibition operation. Description Refer to page 46 for details. Syntax [:SOURce:]CONFigure:INHibit Query Syntax [:SOURce:]CONFigure:INHibit? Parameter/ Return parameter LIVE TRIG EXCITE Example [:SOURce:]CONFigure:INHibit? LIVE [:SOURce]:PHASe:ON Query Set or query waveform start phase angle set at Description main menu.
  • Page 95: [:Source]:List:count

    REMOTE OPERAION Effective rang: 0 ~ 360.0, 360.0 Parameter/ <NR2> Return parameter representing turn off immediately Example [:SOURce:]PHASe:OFF? 250.5 [:SOURce]:LIST:COUNt Query Set or query how many times to execute effective Description sequences in LIST mode. Syntax [:SOURce:]LIST:COUNt Query Syntax [:SOURce:]LIST:COUNt? Effective rang: 0 ~ 10000 Parameter/ <NR1>...
  • Page 96: [:Source]:List:voltage:ac:start

    ASD-1300 User Manual Syntax [:SOURce:]LIST:SHAPe Query Syntax [:SOURce:]LIST:SHAPe? Parameter/ A|B… Return parameter Example [:SOURce:]LIST:SHAPe? A B A A A [:SOURce]:LIST:VOLTage:AC:STARt Query Set or query start voltage of 10 individual Description sequences in LIST mode. Syntax [:SOURce:]LIST:VOLTage:AC:STARt Query Syntax [:SOURce:]LIST:VOLTage:AC:STARt? Effective rang: Parameter/ <NR2>…...
  • Page 97: [:Source]:List:freqency:start

    REMOTE OPERAION [:SOURce]:LIST:FREQency:STARt Query Set or query start frequency of 10 individual Description sequences in LIST mode. Syntax [:SOURce:]LIST:FREQency:STARt Query Syntax [:SOURce:]LIST:FREQency:STARt? Effective rang: 30.0 ~ 1000.0 (unit: Hz) Parameter/ <NR2>… Return parameter <NR2> Example [:SOURce:]LIST:FREQency:STARt? 50.8 80.5 2.2 [:SOURce]:LIST:FREQency:END Query Set or query stop frequency of 10 individual Description...
  • Page 98: [:Source]:Pulse:voltage:ac

    ASD-1300 User Manual Example [:SOURce:]LIST:DEGRee:END? 30.6 96.5 88.0 71 [:SOURce]:PULSe:VOLTage:AC Query Set or query AC voltage of PULSE waveform. Description Syntax [:SOURce:]PULSe:VOLTage:AC Query Syntax [:SOURce:]PULSe:VOLTage:AC? Effective rang: Parameter/ <NR2>… 0.0 ~ 150.0 (low voltage range), Return parameter <NR2> 0.0 ~ 300.0 (high voltage range) Example [:SOURce:]PULSe:VOLTage:AC? 250.1...
  • Page 99: [:Source]:Pulse:count

    REMOTE OPERAION Example [:SOURce:]PULSe:SPHase? 60.0 [:SOURce]:PULSe:COUNt Query Set or query how many times to execute PULSE Description voltage. Syntax [:SOURce:]PULSe:COUNt Query Syntax [:SOURce:]PULSE:COUNt? Effective rang: 0 ~ 10000 Parameter/ <NR1> Return parameter Example [:SOURce:]PULSe:COUNt? [:SOURce]:PULSe:DCYCle Query Set or query execution time of PULSE waveform, Description it must be no longer than total period in PULSE mode.
  • Page 100: [:Source]:Step:voltage:ac

    ASD-1300 User Manual Effective rang: 2 ~ 60000 (unit: msec) Parameter/ <NR1> Return parameter Example [:SOURce:]PULSe:PERiod? [:SOURce]:STEP:VOLTage:AC Query Set or query start voltage for STEP mode. Description Syntax [:SOURce:]STEP:VOLTage:AC Query Syntax [:SOURce:]STEP:VOLTage:AC? Effective rang: Parameter/ <NR2> 0.0 ~ 150.0 (low voltage range), Return parameter 0.0 ~ 300.0 (high voltage range) Example...
  • Page 101: [:Source]:Step:dfreqency

    REMOTE OPERAION Effective rang: 30.0 ~ 1000.0 (unit: Hz) Parameter/ <NR2> Return parameter Example [:SOURce:]STEP:FREQency? 80.5 [:SOURce]:STEP:DFREQency Query Set or query frequency change of each step in Description STEP mode. Syntax [:SOURce:]STEP:DFREQency Query Syntax [:SOURce:]STEP:DFREQency? Effective rang: -150.0 ~ 150.0(unit: Hz) Parameter/ <NR2>...
  • Page 102: [:Source]:Step:count

    ASD-1300 User Manual Effective rang: 1 ~ 60000.0 (unit: msec) Parameter/ <NR2> Return parameter Example STEP:SPHase? 1000.5 [:SOURce]:STEP:COUNt Query Set or query how many steps to execute STEP Description mode. Syntax [:SOURce:]STEP:COUNt Query Syntax [:SOURce:]STEP:COUNt? Effective rang: 0 ~ 10000 Parameter/ <NR1>...
  • Page 103: [:Source]:Synthesis:phase

    REMOTE OPERAION Syntax [:SOURce:]SYNThesis:AMPLitude Query Syntax [:SOURce:]SYNThesis:AMPLitude? Effective rang <NR2>… Order N=2~N=20, Gain limit 33.33% <NR2> Order N=21~N=30, Gain limit 30.00% Order N=31~N=39, Gain limit 15.00% [:SOURce:]SYNThesis:AMPLitude? 20.55 33.10 2.55 [:SOURce]:SYNThesis:PHASe Query Set or query phase for each order of harmonic Description waveforms.
  • Page 104: Other Commands :Trig

    ASD-1300 User Manual Other Commands :TRIG ..................104 :VERion:DSP? ..............104 :VERion:LCM? ..............104 :VERion:UI? ................. 105 :TRIG Query Set or query trigger status. Disabled when Description OUTPut:MODE = FIXE. Syntax :TRIG Query Syntax :TRIG? Parameter Return parameter OFF RUNNING Example TRIG? TRIG ON...
  • Page 105: Verion:ui

    REMOTE OPERAION Return Parameter S00E02 Example :VERion:LCM? S00E02 :VERion:UI? Query Query firmware version of UI. Description Syntax :VERion:UI? Return Parameter S00E02 Example :VERion:UI? S00E02...
  • Page 106: Appendix

    ASD-1300 User Manual PPENDIX Protection .............. 107 Specifications ............109 Certificate Of Compliance ........112 TTL Pin Assignment ..........113 9-PIN D-SUB female connector ..........113 Remote Inhibit ..............113 AC-ON ................113 FAULT-OUT ..............113 Built In Waveforms ..........114...
  • Page 107: Protection

    APPENDIX Protection ASD-1300 provide software and hardware protections. A1500 SERIES will disconnect output relay to turn off output and display protection status on screen when protection happens. To resume the output, following three errors can be released by long press any key.
  • Page 108 ASD-1300 User Manual breaker** AC mains voltage higher or lower than rating ranges PFC AC Fault PFC OVP Fault Over voltage for PFC Board PFC OTP Fault Over temperature for PFC Board Output abnormal for PFC Board PFC PG Fault * D2A OCP ranges: When Voltage Level is 300V, OCP trigger point is 16A.
  • Page 109: Specifications

    APPENDIX Specifications The operation specifications of ASD-1300 programmable AC Power Source are listed below. All specifications have been tested according to the standard of Delta test procedures. All specifications are based on resistor load with remote sense connection, under 25±2°C unless specified otherwise. Input ratings (AC rms) 220Vac to 240 Vac (single phase) Nominal input voltage...
  • Page 110 ASD-1300 User Manual 0.15% Accuracy 0.0° to 359.9° variable (setting Output on phase resolution 0.1°) Output voltage stability 0.1% Line regulation 0.1% Load regulation Output voltage waveform distortion ratio, Output voltage response time, Efficiency Output voltage waveform ≤ 1% distortion ratio Output voltage response 100 us (TYP) time...
  • Page 111 APPENDIX Store and recall settings, Basic settings: 4 (0~3 Memory Function numeric keys) Arbitrary Wave Number 30 (nonvolatile) of memories General Specifications IEEE 488.2 compliant interface GPIB Complies with the EIA-RS-232 Interface RS-232C specifications External Control I/O EXT Control Between input and Withstand 2210 Vac, 1 minute chassis, output and...
  • Page 112: Certificate Of Compliance

    ASD-1300 User Manual Certificate Of Compliance GOOD WILL INSTRUMENT CO., LTD. declare that the CE marking mentioned product satisfies all the technical relations application to the product within the scope of council: Directive: EMC; LVD; WEEE; RoHS The product is in conformity with the following standards or other normative documents: ◎...
  • Page 113: Ttl Pin Assignment

    APPENDIX TTL Pin Assignment 9-PIN D-SUB female connector Pin number 1 GND Remote inhibit GND AC-ON Signal Pin number 5 FAULT-OUT Signal Remote Inhibit OFF: Disable remote inhibit output function.  LIVE: AC source will turn off (turn on) output ...
  • Page 114: Built In Waveforms

    ASD-1300 User Manual Built In Waveforms DST 0 Order Gain Phase 2.07 9.80 15.80 0.0 2.16 DST 1 Order Gain Phase 1.50 1.50 2.00 DST 2 Order Gain Phase 2.00 1.40 2.00 1.40 1.00...
  • Page 115 APPENDIX DST 3 Order Gain Phase 2.50 1.90 2.50 1.90 1.10 1.50 1.10 DST 4 Order Gain Phase 1.10 2.80 1.40 2.30 1.50 DST 5 Order Gain Phase 1.65 4.20 3.45 1.05 3.00...
  • Page 116 ASD-1300 User Manual DST 6 Order Gain Phase 2.20 5.60 2.80 4.60 3.00 1.40 1.00 DST 7 Order Gain Phase 4.90 1.60 2.70 1.40 2.00 1.10 DST 8 Order Gain Phase 7.35 2.40 4.05 2.10 1.05 3.00 1.65 1.05 1.05 1.20 1.05...
  • Page 117 APPENDIX DST 9 Order Gain Phase 9.80 3.20 5.40 1.20 2.80 1.40 4.00 2.20 1.40 1.40 1.60 1.40 DST 10 Order Gain Phase 17.75 0.0 DST 11 Order Gain Phase 21.25 0.0...
  • Page 118 ASD-1300 User Manual DST 12 Order Gain Phase 24.50 0.0 DST 13 Order Gain Phase 2.30 9.80 15.80 0.0 2.50 DST 14 Order Gain Phase 1.15 4.90 7.90 1.25...
  • Page 119 APPENDIX DST 15 Order Gain Phase 1.15 4.90 DST 16 Order Gain Phase 11.00 180.0 4.05 2.00 180.0 1.30 DST 17 Order Gain Phase 7.17 3.42 180.0 0.80...
  • Page 120 ASD-1300 User Manual DST 18 Order Gain Phase 8.11 3.48 180.0 1.00 DST 19 Order Gain Phase 9.38 3.44 180.0 1.15 DST 20 Order Gain Phase 2.06 180.0 1.77 1.62 180.0 1.23 0.91 180.0 0.54 0.51 0.53 180.0...
  • Page 121 APPENDIX DST 21 Order Gain Phase 3.08 180.0 2.72 2.43 180.0 1.97 1.41 180.0 0.86 0.62 180.0 0.73 0.77 180.0 0.69 0.56 180.0 DST 22 Order Gain Phase 0.13 180.0 4.28 180.0 3.77 3.27 180.0 2.57 1.93 180.0 1.22 0.55 180.0 0.46 0.83...
  • Page 122 ASD-1300 User Manual DST 23 Order Gain Phase 5.74 180.0 5.11 4.44 180.0 3.52 2.63 180.0 1.65 180.0 0.61 1.07 180.0 1.28 1.35 180.0 1.22 0.98 180.0 DST 24 Order Gain Phase 7.35 180.0 6.60 5.74 180.0 4.57 3.41 180.0 2.16 1.04 180.0...
  • Page 123 APPENDIX DST 25 Order Gain Phase 3.41 2.55 9.22 7.68 0.90 0.90 3.88 3.56 0.50 2.34 2.21 DST 26 Order Gain Phase 1.38 5.39 2.29...
  • Page 124 ASD-1300 User Manual DST 27 Order Gain Phase 33.33 0.0 20.00 0.0 13.80 0.0 10.80 0.0 8.50 7.20 6.00 5.00 5.00 4.50 4.00 3.50 2.95 2.50 2.00 2.00 2.00 2.00 2.00...
  • Page 125 APPENDIX DST 28 Order Gain Phase 33.33 0.0 20.00 0.0 13.80 0.0 10.80 0.0 8.50 7.20 6.00 5.00 5.00 4.50 4.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 DST 29 Order Gain Phase 33.33 0.0 20.00 0.0 13.80 0.0 10.80 0.0 8.50 7.20...

This manual is also suitable for:

Asd-1300

Table of Contents