Front View Connectors Layout; Top View (Fuses And Led Indicators); 12-Touchpad Setup File Upload Error Codes - D&R ELECTRONICS F5M-IQ Installation Manual

Table of Contents

Advertisement

IQ-CONTROL BOX FRONT VIEW
IQ-CONTROL BOX TOP VIEW
12. TOUCHPAD FILE UPLOAD ERROR CODES
#
Error Name
1
FIELD_COUNT
2
INVALID_VERSION
3
WRONG_TOUCHPAD
4
UNEXPECTED_RECORD
5
LIGHTBAR_COMM
6
RELAY_COMM
7
FILE_ERR
8
USB_ERR
9
MEMORY_ERR
10
FILE_NOT_FOUND
11
RA_MESG_ERR
15
FILE_OK
Error Description
TPP file fields counts is wrong, file content is wrong
TPP file version is wrong
TPP file is defined wrong TouchPad type
TPP file unexpected record exist, file content is wrong
TouchPad has no communication with LightBar
TouchPad has no communication with Relay Board
TPP file read / write error
Detect USB thumb drive error
Read USB thumb error
There is no TPP file in USB thumb
Road Alert Message Board communication error
TPP file upload successful. No error
11
CONNECTOR #11: DATA
Figure 2
Figure 3: IQ-Control Box
Output LED Indicators And Output fuses
LCD Display
Error 1
Error 2
Invalid TP
Error 4
L Comm Err
R Box Err
Error 7
Init Failed!
Remove Drive
Memory Fault
No TP Files
Error 11
Done!