Page 1
F5M-IQ INSTALLATION MANUAL Model F5M-IQ1 F5M-IQ2 IMPORTANT: Carefully read ALL instructions and warnings before attempting to install and operate this equipment. July 31, 2019...
1. Unpacking & Pre-Installation Check D&R Electronics Co. recommends that you open and examine all shipments within 48 hours of receipt. The INTIMIDATOR IQ systems are shipped pre-assembled and factory tested. All necessary hardware for standard installation is included. Use this pre-installation check list to verify your unit: 1.Confirm contents with the packing slip 2.Examine unit for damaged in transit (i.e.
3. Specifications General Input Voltage ............11 to 16 Volts DC Input Fuse ..............60 Amps (external) Operating Temperature Ranges ......-40 C to +65 Standby Current ............50mA + 10% during IGNITION OFF time-out ….………………………..………….ØmA after time-out Control Box Weight Control Box Physical Dimensions Height .........2 - 1/16”...
4. Installation CONNECTOR #1 PIN 1 — Connect a BLACK 10 AWG wire to battery GROUND. PIN 2 — Connect a RED 10 AWG wire to the POSITIVE side of the battery, using a 60A breaker. PIN 3 — Connect a RED 10 AWG wire to the POSITIVE side of the battery, using the same 60A breaker as PIN 2.
6. F5M-IQ DEFAULT TOUCHPAD CONFIGURATION The touchpad setup is a standard factory default. For setup changes refer to the software manual for program- ming. The labels can be rearranged as per customer’s preference. STBY/PA — Momentary AIR HORN (optional can be programmed to momentary WAIL).
Press SW8 to save and exit programming 8. F5M-IQ VOLTAGE CALIBRATION The F5M-IQ system provides a continuous battery voltage reading on the touchpad’s display. After a set- up update, the display will show “Voltage 0V” even though the voltage input is connected to the battery.
9. F5M-IQ TEMPERATURE CALIBRATION (optional equipment) The F5M-IQ system provides an optional connection for up to 3 temperature sensor modules. To calibrate the temperature follow these steps: Step 1: Using a thermometer, record the temperature were the temperature sensor is installed.
WARRANTY D & R Electronics warrants its new products to be free from defects in material and workman- ship, under normal use and service for a period of three years on parts replacement. This warranty applies only to original purchasers acquiring the product directly from D&R Electronics, or its authorized dealers.