Result: The display will return to the default screen.
To reset the connection setting to the factory
default
Reset the connection setting to the factory default in case you want
to:
▪ switch between the WPS and the AP connection option,
▪ disconnect the Wi-Fi adapter and the communication device (e.g.
router) or smart device,
▪ repeat the setting if the connection was unsuccessful.
1 Hold
for at least 5 seconds in the default screen.
Result: The confirmation display (menu  ) appears.
2 Press repeatedly
or
3 Hold
for at least 2 seconds to confirm the selection.
Result: "Beep" sound is heard when the unit receives signal.
Result: The setting is reset to the factory default.
4 Press
to exit the menu.
Result: The display will return to the default screen.
To turn off the wireless LAN connection
You can turn off the wireless connection using:
▪ the wireless adapter ON/OFF button on the unit,
▪ the user interface.
To use the wireless adapter ON/OFF switch
1 Press the wireless adapter ON/OFF switch.
Result: The wireless adapter communication is OFF.
Note:
Press the ON/OFF switch again to turn on the wireless
adapter.
To use the user interface
1 Hold
for at least 5 seconds in the default screen.
Result: The confirmation display (menu  ) appears.
2 Press repeatedly
or
3 Hold
for at least 2 seconds to confirm the selection.
Result: "Beep" sound is heard when the unit receives signal.
Result: Communication is OFF.
4 Press
to exit the menu.
Result: The display will return to the default screen.
FTXTA30C2V1B(W)(B)
Daikin room air conditioner
3P728539-2D – 2023.09
until the menu  appears.
until the OFF menu appears.
6 Energy saving and optimum operation
6
Energy saving and optimum
operation
INFORMATION
▪ Even if the unit is turned OFF, it consumes electricity.
▪ When the power turns back on after a power break, the
previously selected mode will be resumed.
CAUTION
NEVER expose little children, plants or animals directly to
the airflow.
NOTICE
Do NOT place objects below the indoor and/or outdoor unit
that may get wet. Otherwise condensation on the unit or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping, and objects under the unit may get dirty or
damaged.
WARNING
Do NOT place a flammable spray bottle near the air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.
CAUTION
Do NOT operate the system when using a room
fumigation-type insecticide. Chemicals could collect in the
unit, and endanger the health of people who are
hypersensitive to chemicals.
7

Maintenance and service

7.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance.
About the refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
NOTICE
Applicable legislation on fluorinated greenhouse gases
requires that the refrigerant charge of the unit is indicated
both in weight and CO
2
Formula to calculate the quantity in CO
tonnes: GWP value of the refrigerant × total refrigerant
charge [in kg]/1000
Contact your installer for more information.
NOTICE
Maintenance MUST be done by an authorised installer or
service agent.
We recommend performing maintenance at least once a
year. However, applicable legislation might require shorter
maintenance intervals.
equivalent.