IFM Electronic efector200 OJ50 laser Operating Instructions Manual page 8

Diffuse reflection sensor with background suppression

Advertisement

If the setting of the sensitivity is not possible (e.g. object signal and back-
ground signal are about the same), the red LED flashes after step 3 for ap-
prox 2 s The unit then passes into the operating mode with the sensitivity
being unchanged
If the setting button is not activated for 15 minutes during the programming
process, the unit passes automatically into the operating mode with the
sensitivity being unchanged
6.2 Setting of the maximum sensitivity*
Go into the programming mode of the unit. (→ step 1).
Align the unit so that no light is reflected (min. distance > max. range).
Press the setting pushbutton twice (steps 2 and 3).
* The maximum sensitivity can also be set in exactly the same way using the programming
wire (pin 2 / WH). To activate the functions the programming wire is connected to
L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
6.3 Electronic lock
Activate the lock by connecting the programming wire for about 15 s -20 s*
De-activate the lock by connecting the programming wire again for 15 s - 20 s*
* To activate the functions the programming wire (pin 2 / WH) is connected to L+ (pin 1 / BN)
for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
6.4 Programming the output function*
Press for 10 s
* The output function can be programmed in exactly the same way using the programming
wire (pin 2 /WH). To activate the functions the programming wire is connected to
L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
8
>
The red LED starts to flash fast after 2 s
>
Then the yellow and green LEDs flash
alternately
>
After 10 s all LEDs go off, the output
function has changed from light-on mode
to dark-on mode (or vice versa).