Short user's manual
®
VWR
UHP line
®
VWR
EHP line
®
VWR
Standard line
®
VWR
EHP, fixed volume
This short user's manual is
intended to provide a brief
overview of the main features
and operation of all VWR
Single- and Multi-channel
Pipettors.
For detailed information, please
refer to the User Manuals that
can be found at
in several languages.
PMS 647C
CMYK 96/54/5/27
®
www.vwr.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the avantor UHP line and is the answer not in the manual?

Questions and answers

Summary of Contents for VWR avantor UHP line

  • Page 1 ® EHP, fixed volume This short user’s manual is intended to provide a brief overview of the main features ® and operation of all VWR Single- and Multi-channel Pipettors. For detailed information, please refer to the User Manuals that can be found at www.vwr.com...
  • Page 2: Getting Started

    (i.e., the aspirated liquid does not come in contact with the shaft or plunger of the pipettor). Variable volume pipettors Push button Ejector button Volume lock ® (VWR EHP and  ® UHP only) Volume display Tip ejector Shaft...
  • Page 3 They can accommodate volumes from 0.1 µL to 10,000 µL depending on the model. They are available in single-, 8- and 12-channel variable volume as well as fixed volume single-channel versions. EHP, fixed volume ® Push button Ejector button Handle Tip ejector Shaft...
  • Page 4: Set The Volume

    Step 1 Set the volume ® ® Standard 2.16 µL 1.25 mL ® 20.42 µL 1,000 µL Lock the volume ® ® ® NOTE: VWR Standard Single- and Multi-channel Pipettors do not feature a volume lock function.
  • Page 5 Step 2 Insert the tip...
  • Page 6 Ejector adjustment ® ® Standard Pipettors 5,000 and 10,000 µL ® NOTE: Ejector adjustment is not necessary in VWR pipettors as they feature a long ejector stroke.
  • Page 7 Step 3 Aspirate the liquid ~1 sec.
  • Page 8 Recommended depth > 1,000 µL 101-1,000 µL 0.1-1 µL 1-100 µL ≤1 mm 2-3 mm 2-4 mm 5-7 mm Step 4 Dispense the liquid 10°-40°...
  • Page 9 Step 5 Eject the tip...
  • Page 10 Step 6 Calibration ® ® Standard Calibration key ® ® NOTE: Before calibration, in the VWR EHP and VWR UHP lines, always remember to lock the volume using ® the lock function and for the VWR Standard hold the calibration knob.
  • Page 11 ® Calibration key – flat end “Calibration” position “Operating” position Calibration key – cross end...
  • Page 12: Warranty

    (5) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or refund the purchase price of this product to the customer, provided it is returned during the warranty period.
  • Page 13 Safety Notes • The pipettor is designed for the transfer of liquids only using the tip. Do not aspirate liquids without the tip attached. The aspirated liquid should not enter the pipettor, as it may cause damage. • Single-use tips reduce the risk of contamination of samples.
  • Page 14 Legal address of Manufacturer Europe VWR International bv, Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven +3216385011 be.vwr.com United States VWR International LLC 100 Matsonford Rd Radnor, PA 19087 +1 800-932-5000 www.vwr.com...
  • Page 15 Tel.: +36 (52) 521-130 Tel.: +47 22 90 00 00 Email: info.at@vwr.com Email: info.hu@vwr.com Email: info.no@vwr.com Poland Belgium India VWR International Sp. z o.o. VWR International BV VWR Lab Products Private Limbowa 5 Researchpark Haasrode 2020 Limited 80-175 Gdańsk Geldenaaksebaan 464 No.139.