Installation

Installation

Mount the Equipment

To prevent fire and explosion, locate equipment
away from all flammable and combustible materials.
To avoid burns, mount in a location where operators
will not come in contact with hot metal surfaces of
the equipment. Insulate and label lines and
components exiting equipment that may become
hot.
The equipment may be mounted vertically or
horizontally. See F
. 1 and F
IG
Follow the Pressure Relief Procedure, page 12,
before moving the equipment.
1. Ensure that the mounting surface is level and can
support the weight of the equipment, fluid, lines,
and accessories, as well as the stress caused
during operation.
2. For all mountings, be sure the equipment is firmly
secured with fasteners through the mounting feet to
the mounting surface. See Dimensions, page 29,
and F
. 3.
IG
8
. 2.
IG
NOTE: For ease of operation and service, mount the
equipment so the electrical wiring port (C), fluid inlet
port (A), and fluid outlet port (B)are easily accessible.
NOTE: To ensure fluid contact with heating elements,
mount the equipment so that the fluid outlet port (B) is
above the fluid inlet port (A). See Typical Installation,
page 7.
NOTE: A pressure relief valve is required. Install the
pressure relief valve (G) downstream from the
equipment, as close to the outlet port (B) as possible.
See F
. 1 and F
. 2.
IG
IG
NOTICE
To prevent equipment damage, use all fastener holes
to firmly secure all feet to the mounting location.
F
. 3: Mounting Holes
IG
mounting feet
3A8940A