Start and Adjust the Equipment

Thermal expansion can cause over-pressurization,
resulting in equipment rupture and serious injury from
splashing fluids. Do not pressurize the system when
preheating the equipment.
NOTICE
Heated equipment must always contain fluid when
the power is on. Never turn on heat zone switches
while equipment is empty. Heating empty equipment
may cause equipment damage.
See your separate temperature controller manual for
directions on operating the system.
3A8940A
Determine Heater Temperature
For maximum equipment life, use the lowest
temperature setting needed.
NOTICE
Operating the equipment at its highest setting, 203°F
(95°C), for long periods of time decreases the
equipment life. Temperatures higher than necessary
may also cause the fluid to dry out, resulting in a
poor finish and clogged equipment.

Shutdown

1. Perform Flush the Equipment, page 14.
2. Perform Pressure Relief Procedure, page 12.
3. Verify that the equipment is turned off and power to
the system is disconnected.
4. Allow equipment to cool.