Troubleshooting
Problem
Temperature
Low input voltage or voltage
variation
fluctuation
Electrical connections are loose or
damaged
Equipment electrical elements are
damaged
The wrong temperature controller is
installed
Material temperature at the pump
inlet is too low
Material cooling in fluid lines
18
Cause
Solution
The maximum amount of heat depends on the input
voltage. Verify that the correct temperature
controller, voltage, wiring, fusing, sensors, and sizing
of electrical connections are used for your
equipment. See Technical Specifications, page 30
for electrical requirements.
Check for continuity between the electrical terminals
inside the equipment and power source. Ensure
terminal connections are secure. Replace damaged
parts as needed.
Check electrical continuity. Replace heater elements
as needed.
Verify that the correct temperature controller for your
equipment is installed. See Technical
Specifications, page 30, for electrical requirements.
Increase the temperature of the material before use.
Use a fluid line that maintains the temperature of the
fluid while the fluid travels through the line.
3A8940A