However, there is no NetZero Fire stands for innovation and quality. This is why guarantee that interference will not occur in a particular we work continuously on the further development of our installation.
Do not install electronics, artwork, or any other humidity must be <85%. item that can be damaged from heat rising from the heater above the heater. NetZero Fire will not • Do not place the fireplace directly under a wall be responsible for any damage to these items.
ASSEMBLY OF THE FIREPLACE Rear Screen Assembly Install the rear screen bracket to the top LED rear screen Required Tools bracket. Use 2 (M5 x 10) screws. - 8mm Nut Driver or Socket - 5mm Allen Wrench - 3mm Allen Wrench - 12mm Wrench - 17mm Wrench - Level...
Page 6
Install the rear screen assembly in the back of the fireplace. Connect the rear screen: 1. HDMI The bracket fits into slots at the back of the fireplace and will rotate forward into the spring clips at the top. 2. Power WARNING: When rotating the screen forward move slowly.
Top Screen Assembly Replace the rear and top panels with 8 (M5 x 10) screws. The fireplace in now ready to be installed into your wall. Remove the protective film from the top screen before installing it into the fireplace. The pegs at the front of the screen rest on brackets as shown below.
INSTALLING THE FIREPLACE Ventilation Openings The chase the fireplace is installed in must have sufficient ventilation for the fireplace to function correctly. A Light / Illumination minimum of 15 ½ in (100 cm ) of free area is required. The E-one functions on the basis of hologram technology. One way to accomplish the required ventilation is to cut a This involves the use of a glass reflector that is placed at an hole in the chase and install a 10”...
Temperatures above the heat outlet on the fireplace can reach temperatures up to 175°F. Materials used in this area must be rated for these temperatures. NetZero Fire is not responsible for damage to walls because of the use of improper materials or installation.
SETTING UP THE FIREPLACE Fireplace with the design bottom plates installed. Place the fireplace in its final position before continuing to set up the fireplace. Level the fireplace using the adjustable legs. Once you have levelled the fireplace, it is strongly recommended that you attach it to the wall using the wall brackets for added stability and safety.
Log Set Installation The logs are made of fragile material. Therefore, proceed with extreme caution when installing the logs. NOTE: Log set instructions are shown with the flat bottom floor installed in the fireplace. When installing the log set it is important that the logs are places exactly as shown in these instructions. If logs are not placed correctly the projected flame will not line up with the logs.
Page 12
Place the next three logs on the ember bed as shown. Next place log “K” on the right side of the ember bed. Log “O” is placed so that it is resting on log “P”. The placement of logs “P” and “O”...
Placing Glass Reflector Placing Upper Side Walls Install the upper side walls in the fireplace. Install the side walls by placing the bottom point against the extrusion on the glass reflector. Then rotate the side wall towards the wall and the magnet will hold it in place. The glass reflector is susceptible to stains and fingerprints.
Wear the included gloves to handle the front window. Place IMPORTANT: If you do not intend to use the unit for a long the front window into the two holders at the front of the period of time, we advise you to switch off the unit by fireplace.
Anti-Reflect Function E-One Remote and Symbols When the fireplace is on briefly press the power button to turn the fireplace off with the anti-reflect mode activated. In this standby mode, the fireplace will be attractively lit. This provides a nice view of the logs, even when the fire is Atmos Heating (ON/OFF switch) not burning.
MAINTENANCE Lean the top of the glass down and carefully remove it from the fireplace. The glass reflector can now be accessed and CAUTION: Before cleaning, make sure the power has been cleaned. turned off at the circuit breaker panel and that the heating element of the heater is cool.
NetZero Fire dealer if pre-approved by NetZero Fire, is fireplace. responsible for all infield diagnosis and service work related to all warranty claims. NetZero Fire is not responsible for results or costs of workmanship of unauthorized NetZero Fire dealers or agents in the negligence of their service work.
Dimension Drawing For framing the fireplace follow the framing dimensions and instructions given in this manual. Warning: The ceiling of the enclosure must be at least 6” above the top of the heater or 11 ½” above the top of the fireplace.
Page 20
1155 Sherman Rd, Hiawatha, IA 52233 (800)553-5422 NetZero is a distributor of these products, which are designed and manufactured by Kalfire B.V. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AND SUPPLIED MANUALS. IMPLIED WARRANTIES OF MERCHANTABILITY, IMPLIED WARRANTIES OF FITNESS, IMPLIED...