NetZero Kalfire E-one 130F Installation And Operation Manual

Hide thumbs Also See for Kalfire E-one 130F:

Advertisement

Quick Links

INSTALLATION AND OPERATION MANUAL
Please read these instructions completely before
installing or operating the E-one fireplace.
NetZero Kalfire E-one Electric Fireplace
Models: AA-11-05387 – E-one 130F
IMPORTANT
Please read these instructions carefully before installation.
Failure to follow them could result in serious injury.
This appliance must be installed by a qualified installer.
The installation and wiring connections must be done in accordance with the
national and local codes having jurisdiction.
For use with 120V 60Hz electrical supply only.
This appliance must be grounded.
The heater outlet becomes hot while in operation.
Never cover the heater outlet or any other part of the appliance.
SAVE THESE INSTRUCTIONS
85-03-01291
NetZero Fireplace ©2023 All rights reserved. 0623

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kalfire E-one 130F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NetZero Kalfire E-one 130F

  • Page 1 For use with 120V 60Hz electrical supply only. This appliance must be grounded. The heater outlet becomes hot while in operation. Never cover the heater outlet or any other part of the appliance. SAVE THESE INSTRUCTIONS 85-03-01291 NetZero Fireplace ©2023 All rights reserved. 0623...
  • Page 2: Table Of Contents

    Table of contents 1 INTRODUCTION 1.1 Receiving Inspection 1.2 Certification 2 GENERAL SAFETY REGULATIONS 2.1 Additional General Safety Regulations for Atmos Heating 2.2 Disposal 2.3 California Proposition 65 Warning 3 ASSEMBLY OF THE FIREPLACE 3.1 Required Tools 3.2 Included Hardware 3.3 Removal of Covers 3.4 Adjustable Feet 3.5 Rear Screen Assembly...
  • Page 3: Introduction

    However, there is no NetZero Fire stands for innovation and quality. This is why guarantee that interference will not occur in a particular we work continuously on the further development of our installation.
  • Page 4: Additional General Safety Regulations For Atmos Heating

    Do not install electronics, artwork, or any other humidity must be <85%. item that can be damaged from heat rising from the heater above the heater. NetZero Fire will not • Do not place the fireplace directly under a wall be responsible for any damage to these items.
  • Page 5: Assembly Of The Fireplace

    ASSEMBLY OF THE FIREPLACE Rear Screen Assembly Install the rear screen bracket to the top LED rear screen Required Tools bracket. Use 2 (M5 x 10) screws. - 8mm Nut Driver or Socket - 5mm Allen Wrench - 3mm Allen Wrench - 12mm Wrench - 17mm Wrench - Level...
  • Page 6 Install the rear screen assembly in the back of the fireplace. Connect the rear screen: 1. HDMI The bracket fits into slots at the back of the fireplace and will rotate forward into the spring clips at the top. 2. Power WARNING: When rotating the screen forward move slowly.
  • Page 7: Top Screen Assembly

    Top Screen Assembly Replace the rear and top panels with 8 (M5 x 10) screws. The fireplace in now ready to be installed into your wall. Remove the protective film from the top screen before installing it into the fireplace. The pegs at the front of the screen rest on brackets as shown below.
  • Page 8: Installing The Fireplace

    INSTALLING THE FIREPLACE Ventilation Openings The chase the fireplace is installed in must have sufficient ventilation for the fireplace to function correctly. A Light / Illumination minimum of 15 ½ in (100 cm ) of free area is required. The E-one functions on the basis of hologram technology. One way to accomplish the required ventilation is to cut a This involves the use of a glass reflector that is placed at an hole in the chase and install a 10”...
  • Page 9: Wall Dimensions

    Temperatures above the heat outlet on the fireplace can reach temperatures up to 175°F. Materials used in this area must be rated for these temperatures. NetZero Fire is not responsible for damage to walls because of the use of improper materials or installation.
  • Page 10: Setting Up The Fireplace

    SETTING UP THE FIREPLACE Fireplace with the design bottom plates installed. Place the fireplace in its final position before continuing to set up the fireplace. Level the fireplace using the adjustable legs. Once you have levelled the fireplace, it is strongly recommended that you attach it to the wall using the wall brackets for added stability and safety.
  • Page 11: Log Set Installation

    Log Set Installation The logs are made of fragile material. Therefore, proceed with extreme caution when installing the logs. NOTE: Log set instructions are shown with the flat bottom floor installed in the fireplace. When installing the log set it is important that the logs are places exactly as shown in these instructions. If logs are not placed correctly the projected flame will not line up with the logs.
  • Page 12 Place the next three logs on the ember bed as shown. Next place log “K” on the right side of the ember bed. Log “O” is placed so that it is resting on log “P”. The placement of logs “P” and “O”...
  • Page 13: Placing Glass Reflector

    Placing Glass Reflector Placing Upper Side Walls Install the upper side walls in the fireplace. Install the side walls by placing the bottom point against the extrusion on the glass reflector. Then rotate the side wall towards the wall and the magnet will hold it in place. The glass reflector is susceptible to stains and fingerprints.
  • Page 14: One Operation

    Wear the included gloves to handle the front window. Place IMPORTANT: If you do not intend to use the unit for a long the front window into the two holders at the front of the period of time, we advise you to switch off the unit by fireplace.
  • Page 15: E-One Remote And Symbols

    Anti-Reflect Function E-One Remote and Symbols When the fireplace is on briefly press the power button to turn the fireplace off with the anti-reflect mode activated. In this standby mode, the fireplace will be attractively lit. This provides a nice view of the logs, even when the fire is Atmos Heating (ON/OFF switch) not burning.
  • Page 16: Maintenance

    MAINTENANCE Lean the top of the glass down and carefully remove it from the fireplace. The glass reflector can now be accessed and CAUTION: Before cleaning, make sure the power has been cleaned. turned off at the circuit breaker panel and that the heating element of the heater is cool.
  • Page 17: Warranty

    NetZero Fire dealer if pre-approved by NetZero Fire, is fireplace. responsible for all infield diagnosis and service work related to all warranty claims. NetZero Fire is not responsible for results or costs of workmanship of unauthorized NetZero Fire dealers or agents in the negligence of their service work.
  • Page 18: Wire Diagram

    Wire Diagram...
  • Page 19: Dimension Drawing

    Dimension Drawing For framing the fireplace follow the framing dimensions and instructions given in this manual. Warning: The ceiling of the enclosure must be at least 6” above the top of the heater or 11 ½” above the top of the fireplace.
  • Page 20 1155 Sherman Rd, Hiawatha, IA 52233 (800)553-5422 NetZero is a distributor of these products, which are designed and manufactured by Kalfire B.V. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AND SUPPLIED MANUALS. IMPLIED WARRANTIES OF MERCHANTABILITY, IMPLIED WARRANTIES OF FITNESS, IMPLIED...