3-3

Control Panel LEDs

The control panel located on the front of the SC822S-400LP chassis has
five LEDs. These LEDs provide you with critical information related to dif-
ferent parts of the system. This section explains what each LED indicates
when illuminated and any corrective action you may need to take.
Overheat: Indicates an overheat condition in the chassis. This may
be caused by cables obstructing the airflow in the system or the ambient
room temperature being too warm.
that the chassis cover is installed and that all fans are present and operat-
ing normally. Verify that the heatsinks are installed properly (see Section 5-
5 and Figure 5-4). Finally, check the air seals for damage. The air seals
are located under the blower fan and beneath the frame cross section that
separates the drive bay area from the motherboard area of the chassis.

NIC2

NIC2:
Indicates network activity on LAN2 when flashing.

NIC1

NIC1:
Indicates network activity on LAN1 when flashing.
HDD: Indicates IDE channel activity. On the SuperServer 6022P-6,
this LED indicates CD-ROM drive activity when flashing.