EasyBuilder Pro Software Settings
Launch EasyBuilder Pro software, select your
project file, press F7 shortcut key to open
the download dialog box:
Select Ethernet > IP tab > Enter your HMI IP
> Click Download to download this project
file to HMI.
If use MT6071iE, please select USB cable.
( Please refer to EasyBuilder Pro User Manual
for software operation details )
Communication Connections
7
NOTE:
COM2 and COM3 [RS485] 2W support MPI 187.5K, please use one at one time.
PIN#
Symbol
9 Pin, Male, D-sub
COM1 [RS232]
1
Not used
2
RxD
3
TxD
4
Not used
5
GND
6
Not used
7
RTS
8
CTS
9
Not used
PIN#
Symbol
9 Pin, Female, D-sub
COM2 / COM3 [RS485]
1
Rx-
2
Rx+
3
Tx-
4
Tx+
5
GND
6
Data-
7
Not used
8
Not used
9
Data+
8
DIP SW Settings
SW1
SW2
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
COM1 [RS232]
Received Data
Transmitted Data
Signal Ground
Ready to send output
Clear to send input
Com2
Com2
Com3
[RS485]2w
[RS485]4w
[RS485]
Data-
Rx-
Data+
Rx+
Tx-
Tx+
Signal Ground
Data-
Data+
SW3
SW4
Mode
OFF
Touch Screen Calibration Mode
OFF
OFF
Hide HMI System Setting Bar
OFF
ON
Boot Loader Mode
OFF
OFF
ON
Not supported
OFF
OFF
Normal
NOTE:
Make sure that all local and national electrical standards are met when
CAUTION
installing the unit. Contact your local authorities to determine which codes apply.
HMI
The
can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with
Power
most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 2A.
If the display does not come on within 5 seconds of power up, remove power. An internal fuse will
Fusing
prevent damage if the polarity of the DC power is incorrect. Check wiring for proper connections
Require-
and try to power up again.
ments
An Internal fuse will prevent damage for overcurrent condition however it isn't guaranteed. DC
High
voltage sources should provide proper isolation from main AC power and similar hazards.
Voltage
A Hard-wired EMERGENCY STOP should be fitted in any system using
Emergency
Safety Recommendations.
Stop
HMI
Do not power the
and inductive DC loads, or input circuitry to the controller, with the same
Supply
power supply. Note: The 24 VDC output from some controllers may not have enough current to
Voltage
HMI.
power the
Condition
a. Power wire length should be minimized (Max: 500m shielded, 300m unshielded).
Wire
b. Please use twisted pair cables for power wire and signal wire and conform to the impedance
Routing
matching.
c. If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices.
d. Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires.
e. Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency dissipation.
Typical values to use are 1M Ohm and 4700pF.
DANGER
Hardware
The system designer should be aware that devices in Controller systems could fail and thereby
Considerations
create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to
equipment start-up, which could result in property damage and/or physical injury to the operator.
If you use any programmable control systems that require an operator, be aware that this potential
safety hazard exists and take appropriate precautions. Although the specific design steps depend on
your particular application, the following precautions generally apply to installation of solid-state
programmable control devices, and conform to the guidelines for installation of Controllers
recommended in NEMA ICS 3-304 Control Standards.
To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure
Programming
that all writable registers that control critical parts of plant or machinery have limit checks built into
Considerations
the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.
Limited Warranty
This product is limited warranted against defects in design and manufacture.
The proven defective product will either be repaired or replaced, at Weintek's discretion.
This warranty shall not cover any product which is
(a) Out of warranty period which is 12 months from the manufacturing month of the HMI products.
(b) Damage caused by Force Majeure, accident, negligence, improper installation or misuse.
(c) Product has been repaired or taken apart by unauthorized technicians.