  • Page 1 IR 2050 / IR 3050 OPERATING MANUAL RADIANT HEATER...
  • Page 2: Table Of Contents

    Info Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. radiant heater IR 2050 / IR 3050...
  • Page 3 Order a new power cable with mains plug from appliance in a safe way and understand the hazards Trotec and replace the defective power cable with mains involved. plug with the new one.
  • Page 4 Do not leave the packaging lying around. Children may use it as a dangerous toy. Warning Improper installation entails a risk of fire. Do not place the device on combustible ground. Do not place the device on high-pile carpets. radiant heater IR 2050 / IR 3050...
  • Page 5: Information About The Device

    • approx. 6,000 operating hours with a light reduction of 80 % • only suitable for wall mounting • adjustable angle • no dust circulation (suitable for allergy sufferers) radiant heater IR 2050 / IR 3050...
  • Page 6: Transport And Storage

    Designation • Remove batteries from the remote control. Operating light (behind grille) On/off switch Wall holder with adjustable inclination angle Remote control Heating rod Grille Infrared receiver for remote control radiant heater IR 2050 / IR 3050...
  • Page 7: Assembly And Start-Up

    50 cm 50 cm 50 cm 180 cm 4. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding. radiant heater IR 2050 / IR 3050...
  • Page 8 5. Check the mounting brackets for tight fit. 6. Screw the device onto the mounting brackets. To do so, fasten the wall holders to the mounting brackets using the fastening screws and wing nuts. radiant heater IR 2050 / IR 3050...
  • Page 9 • Insert the mains plug into a properly fused mains socket. • Make sure that the power cable is guided along the back of the device. Never guide the power cable along the front of the device! radiant heater IR 2050 / IR 3050...
  • Page 10: Operation

    1. Press the P1 button (12) to switch the device on at level 1. ð During operation the operating light (1) is permanently illuminated in green. ð The device heats. 2. To set a higher heating capacity press either the P2 button (10) or the P3 button (11). radiant heater IR 2050 / IR 3050...
  • Page 11: Available Accessories

    Order a new power cable with mains plug from device to 0. The operating light flashes red. Trotec and replace the defective power cable with mains • Allow the device to cool down completely. plug with the new one.
  • Page 12: Maintenance

    Wipe the housing dry after cleaning. Dirt on the heating rods should be removed with a long brush with soft bristles. radiant heater IR 2050 / IR 3050...
  • Page 13: Technical Annex