③ Display the input screen of the item data you
desire to change.
Data which are possible to be changed are 9 items
below.
Item
B
Scale rate in X direction
C
Scale rate in Y direction
D
Thread tension
E
Max. speed limitation
Travel amount in X
F
direction
Travel amount in Y
G
direction
H
Sewing shape
I
Folder No.
J
Thread clamp
When each button from B to H is pressed, the item
data input screen is displayed. When the buttons of
I and J are pressed, Folder Nos. and With/without
thread clamp are changed over.
B Scale rate in X direction and C Scale rate in Y
*
direction can be changed to the actual size value
input by selection of memory switch
*
Range of max input of max. limitation speed (E)
and the initial value are determined with memory
switch U01.
*
When the prohibition of thread clamp is set with
memory switch U35, the button of thread clamp
(J) is not displayed.
Input range
Initial value
100
20 to 200 (%)
100
20 to 200 (%)
50
0 to 200
400 to 3,000
3000
(rpm)
-20.0 to 20.0
0.0
(mm)
-20.0 to 10.0
0.0
(mm)
-
-
-
1 to 5
With/without
With
.
52
H
I
D
F
J
B
C
E
G