JUKI LK-1901A Instruction Manual page 140

Hide thumbs Also See for LK-1901A:
Table of Contents

Advertisement

16 kinds of the sensors below are displayed.
No.
Pictograph
Description of sensor
DIPSW2-1
DIPSW2-2
DIPSW2-3
DIPSW2-4
Optional start SW
Optional presser SW
Optional presser 2 SW
Pedal SW
(Pedal input value is displayed. )
Needle upper dead point (5 to 30 ゚)
Needle lower dead point (185 to 215 ゚)
Needle lower position (80 to 123 ゚)
Needle UP position (40 to 62 ゚)
TG (45 times/rotation)
Feed reference (125 to 155 ゚)
Main motor Z phase (0 to 180 ゚)
Head tilt SW
139