Technical Specifications; General; Electrical Specifications - Sinclair S-Therm Yukon Series User & Installation Manual

Monoblock heat pumps
Table of Contents

Advertisement

14 TECHNICAL SPECIFICATIONS

14.1 General

1-phase
Model
4/6 kW
Nominal capacity
Dimensions HxWxD
718×1295×429mm
Packing
1375*885*475mm
Dimensions HxWxD
Weight (without backup heater)
Net weight
86kg
Gross weight
107kg
Weight (backup heater have be intergrated in the unit)
Net weight
91kg
Gross weight
112kg
Connections
water inlet/outlet
G1"BSP
Water drain
Expansion vessel
volume
Maximum working
pressure (MWP)
Pump
Type
Water cooled
No. of speed
Variable speed
Pressure relief valve
water circuit
heating
cooling
Operation range - air side
heating
cooling
domestic hot water by
heat pump

14.2 Electrical specifications

Power Supply
Standard unit
Nominal Running Current
Power Supply
Backup heater
Nominal Running Current
1-phase
1-phase
8/10 kW
12/14/16 kW
Refer to the Technical Data
865×1385×526mm
865×1385×526mm
1465*1035*560mm
1465*1035*560mm
105kg
129kg
132kg
155kg
134kg
110kg
160kg
137kg
G5/4"BSP
G5/4"BSP
hose nipple
8L
8 bar
Water cooled
Water cooled
Variable speed
Variable speed
3 bar
+12~+65°C
+5~+25°C
-25~35°C
-5~43°C
-25~43°C
1-phase 4/6/8/10/12/14/16kW
220-240V~ 50Hz
See "9.7.4 Safety device requirement"
See "9.7.4 Safety device requirement"
76
3-phase
12/14/16 kW
865×1385×526mm
1465*1035*560mm
144kg
172kg
149kg
177kg
G5/4"BSP
Water cooled
Variable speed
3-phase 12/14/16kW
380-415V 3N~ 50Hz

Advertisement

Table of Contents
loading

Table of Contents