600
60
700
60
800
60

Operating Parameters

900
60
Use this graph to estimate solar load and its effect on maximum safe ambient temperature for the display.
Maximum Ambient Temperature vs Solar Load
Shade
62
60
58
56
54
52
50
0
100
Kiosks will incur an additional 5°C minimum temperature rise with the disclamer that insufficent airflow, high surface
area to volume ratio, additional internal electronics, and dark exterior colors will incur a higher temperature rise.
Peerless-AV Engineering should be consulted in these situations.
Peerless-AV Engineering must be consulted before placing the display into any enclosure not developed by
Peerless-AV. Peerless-AV Engineering management must approve this installation solution to support the native
warranty of the display.
5.4
54.6
6.4
53.6
7.6
52.4
10.2
49.8
Partial
Indirect Full
200
300
400
Full
500
600
Solar Load (W/m
2
)
7
Intense
700
800
900