SYSTEM INSTALLATION AND ELECTRICAL REQUIREMENTS

Electrical Code

Note: To the display system installer: This reminder is provided to call attention to Article 820-44 of the National
Electric Code that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall
be connected to the grounding system of the facility. Outlet shall be installed near the equipment and shall be easily
accessible.
NEC National Electric Code
Note: Installation shall incorporate UL Listed external surge protection rated 2500 Vpk or less, for 150 to 300 Vac
mains, installed in accordance with Article 285 of ANSI/NFPA 70 or applicable local codes.

Power Source

The display must be connected to a mains socket outlet with a protective grounding connection.
The mains plug is used as the disconnect device and shall remain readily accessible.
Electrical installation shall be in accordance with the applicable parts of Chapter 8 of ANSI/NFPA 70.
An outdoor antenna should not be located near overhead electrical lines or any electrical circuits.
If an outside antenna is connected to the receiver, confirm that the antenna system is grounded to protect against
voltage surges and built up static charges. Section 810 of the National Electric Code, ANSI/NFPA No 70-1984,
provides information with respect to proper grounding for the mast and supporting structure, grounding of the lead-in
wire to an antenna discharge unit, size of grounding connectors, location of antenna discharge unit, connection to
grounding electrodes and requirements for the grounding electrode.
This display operates on 100-240 volts 50-60 Hz, AC current. Never connect the display to direct current or anything
other than the specified voltage.
To prevent electric shock from the display, do not use with an extension cord, receptacle, or other outlet unless the
blades and ground terminal can be fully inserted to prevent blade exposure.
All secondary lines must be routed through grounded conduit and kept separate from AC line.
Ground clamp
Electric service
equipment
Ground clamps
Antenna lead-in wire
Antenna discharge unit
(NEC Section 810-20)
Grounding conductors
(NEC Section 810-21)
Power service grounding
electrode system
(NEC Art 250 Part H)
2
2022-07-06
#:180-9147-1