11. Removal Procedure
Service Manual

11.2 Removal Procedure of Outdoor Unit

09K
NOTE:Take heat pump for example.
Step
1. Remove cable cross plate sub-assy and valve
cover
Remove the screws connecting cable cross
plate sub-assy and right side plate, to remove
the cable cross plate sub-assy. Remove the
screw fixing valve cover, to remove the cover.
2. Remove top cover
Remove connection screws connecting
the top panel with the front panel and the
right side plate, and then remove the top
panel.
3. Remove grille, protective grille and front panel
Remove connection screws between the front grille
and the front panel. Then remove the front grille.
Remove connection screws connecting the front
panel with the chassis and the motor support, and
then remove the front panel.
Remove the screws fixing protective grille and then
remove the protective grille.
Installation and Maintenance
Caution: discharge the refrigerant
completely before removal.
Procedure
grille
cable cross
plate sub-assy
valve cover
top cover
protective
grille
panel