Download Print this page

Pentair INTELLICHLOR COMSYS-6 Installation Manual page 3

Salt chlorinator commercial system

Advertisement

®
IntelliChlor
Salt Chlorine Generator (SCG) COMSYS-6 Overview
The IntelliChlor COMSYS-6 commercial system consists of four IntelliChlor (SCG) cells and three power
centers (one primary and three secondary).
Each cell can produce up to 2.00 lbs of pure chlorine per 24 hours of operation. These cells can sanitize either a
pool or spa, or combination of both. A commercial system requires an external ORP panel and sensor to
produce chlorine upon demand as needed. The ORP system is sold separately.
Features
Each cell draws approximately 220 Watts.
Dry contact wires on primary power center connect to chlorine controller panel (ORP system).
Closing these wires turns the Comsys system on with an output level of 100%. The system is now
producing chlorine. Opening these wires turns the Comsys system off with an output level of 0%, so
the system is not producing chlorine.
Each cell produces 2.00 pounds of chlorine per 24 hours.
Comsys-6 (3-cell - 1 primary and 2 secondary) produces six pounds of chlorine per day.
The ORP system (not provided) is a separate device that monitors the available chlorine in the water
and, when needed, calls for chlorine to be produced by closing a dry contact output. An ORP system
consists of a panel, usually with an LCD display, that has the ORP sensor in the water.
Preparing the Site
1. Add salt to the water until it measures 3600 ppm. Use an electronic tester to measure salt, such as
the Extech EC400. DO NOT USE SALT TEST STRIPS AS THEY TEND TO BE INACCURATE.
Allow the salt to mix for 24 hours before using the IntelliChlor system.
2. Locate a clear spot on a wall, within 15 feet of the IntelliChlor manifold.
3. Locate a clear spot on the return line where the IntelliChlor manifold will be mounted. Be sure that
the user can readily see the lights and press buttons if needed.
4. Be sure 110VAC or 220VAC is available and on its own circuit breaker, to power the IntelliChlor
power centers. This separate breaker will make it easier to service the IntelliChlor.
5. Be sure 110VAC or 220VAC is provided to the power center bank in a conduit, for maximum safety
and NEC compliance.
IntelliChlor Salt Chlorine Generator COMSYS-6 Installation Guide
1

Advertisement

loading

This manual is also suitable for:

Intellichlor 520972