MLG33 – Gas
ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY . For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
WIRE
PHASE
VOLTAGE
SERVICE
120
14
APPROX.
CIRCUIT
AMP DRAW
BREAKER
60 Hz
50 Hz
2
10.3
15
All electrically heated dryers must be connected to the electric
service shown on the dryer's data label. The connecting
wires must be properly sized to handle the rated current.
6/2/05
Maytag Co.
113413-1