Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies. – L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. Maytag Co. 113489 - 3 (W10185535)
Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt. The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel. See installation instructions for grounding requirements. SAVE THESE INSTRUCTIONS Maytag Co.
The dryer must be installed with adequate clearance for air openings into the combustion chamber. IMPORTANT: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C). Maytag Co. 113489 - 3 (W10185535)
WARNING Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. Maytag Co.
Page 8
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Maytag Co. 113489 - 3 (W10185535)
Page 9
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Maytag Co. 1638 1290 45.72 40.64 35.56...
Remove 3 screws holding down electrical box plate at the 1/9/08 top of the machine. Remove 2 knockouts provided just in front of electrical box and insert 3/4” UL listed strain relief into the holes. Maytag Co. WARNING Fire Hazard 113489 - 3 (W10185535)
Failure to isolate or disconnect the dryer from supply as Green noted can cause irreparable damage to the gas valve, voiding the warranty. Ground NOTE: Undersized gas piping will result in ignition problems, slow drying, and increased use of energy. Maytag Co. WARNING Explosion Hazard...
• Rotate the tumbler (drum) by hand to be sure it moves freely. • Check bolts, nuts, screws, terminals, and fittings for tightness and security. • Check that the vent is connected to the dryer and is exhausted to the outdoors. Maytag Co. TYPICAL NATURAL GAS INSTALLATION 113489 - 3 (W10185535)
Maytag distributor from whom the equipment was purchased. If the distributor cannot be contacted or is unknown, contact the Maytag Co. for a distributor in your area. NOTE: When contacting the Maytag Co., be sure to give them the correct model number and serial number so that your inquiry is handled in an expeditious manner.
Data Label Information ________________ Standard Label When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the lower left rear of the dryer behind the back guard.