EMERGENCY STOP DEVICE
The machines are equipped with an emergency stop device in accordance with ISO13850 - category 0 stop
function. Nevertheless, the emergency stop device is omitted on machines designed for coin, token, external
payment system or similar operation for use in self-service situation. The owner-installer-user must provide
remote-located emergency stop device(s). This emergency stop device(s) needs to stop each machine
in accordance with ISO13850 - category 0. There are made provisions in the wiring harness, were immediate
removal of power to the actuators can be accomplished. See the electrical schematic of the machine for correct
connection of the device.
CHECKING ROTATION DIRECTION
Check if the drum rotates from the front view in clockwise direction during extraction. If it rotates in opposite
direction, disconnect two phases wires of the connection from the frequency inverter to the motor , switch
them over and check again the rotation direction.
MULTIPLE MACHINES IN LINE SINGLE PHASE
When multiple single phase machines are connected to the same electrical network, it is necessary to connect
the machines according to fig.4.5.E. The phase of the frequency control and motor which is connected
to the terminal inside the machine, has to be connected alternatively for the first machine with the first phase
L1 of the network, the second machine with the second phase L2, ... The fourth machine must again be connected
to the first phase L1. This assures a better load of the electrical network.

4.6. WATER CONNECTION

The washer is equipped with 3/4" BSP (British Standard Pipe Thread) hot and cold water inlet valves, indicated
by a sticker next to the inlet. Use the water inlet hoses that accompany the washer as they are properly adapted
to the water valves and appliance. NEVER use a rigid connection to the water supply.
There are 2 kinds of water inlet hoses, water inlet hoses with at both sides BSP threaded nuts or at one side
a BSP nut and a NPT nut on the other end. The NPT Nut is marked with groove.
For best operation of the washer, water pressure must between 43 - 73 PSI (pound per square inch)
or 0.3 - 0.5 MPa. Water pressure that is below minimum requirements can lengthen the wash cycle
or/and not allow proper function of the washer.
100646G MAYTAG PUB DATE 28 JUN 2007.DOC
Fig.4.5.D Spin direction
Fig.4.5.E Multiple machines in line
INSTALLATION AND MAINTENANCE MANUAL
17