Checking Components For Proper Operation - Electrolux Talkie Service Manual

Table of Contents

Advertisement

11.2 Checking components for proper operation

To make it easier to check components, a TEST PROCEDURE has been developed which indicates the
points where tester probes should be applied and the correct theoretical value for each component.
Access the electronic board positioned on the basement and detach all the connectors.
Connect the probes of the tester to the appropriate points. Compare the electric resistance reading with
the value shown on the table
Measurement points on circuit board wiring connectors:
LIST OF COMPONENTS
* POWER CABLE &
(PU) - ON/OFF SWITCH
(RR) - HEATING ELEMENT +
(TS) - SAFETY THERMOSTAT
(PR) - LEVEL PRESSURE SWITCH
(PA) - ANTI-FLOODING PRESSURE
SWITCH
(IP) - DOOR MICROSWITCH
(DD/DB) - INTEGRATED DISPENSER
(SB) - RINSE-AID SENSOR
(SS) - SALT SENSOR
(ST) - TEMPERATURE SENSOR
(GT) - TACHOMETRIC SENSOR
(MV) - FAN MOTOR
(ER) - REGENERATION SOLENOID
(EC) - FILL SOLENOID +
(AA) - ANTI-FLOODING DEVICE
(PL) - WASH MOTOR
(PS) - DRAIN MOTOR
Note: - * = Measurement points L and N refer to the pins on the plug fitted to the power cable.
** = Fill in about 4l water so that the level pressure switch is on full position.
PROBE
CORRECT VALUES
CONTACTS
L
E1
N
E3
E1
E2
E1
B1
B5
E3
F1
F3 on the
Input board
A3
A5
C1
C3 on the
Output board
H1
H3
H7
H8
G1
G2
D1
D3
F1
F3
A1
A2
F5
F7
To the two motor
wires (blue) / (red)
B5
F7
38
NOTES
0 Ω
with ON/OFF button
pressed
0 Ω
connected in series
25 Ω ± 8%
(2100W)
INFINITE
on EMPTY (1-2)
0 Ω
on FULL (1-3)
INFINITE
on EMPTY (1-2)
0 Ω
on FULL (1-3)
0 Ω
Door closed
1500 Ω ± 8%
OK
INFINITE
with Rinse-aid
0 Ω
without Rinse-aid
INFINITE
with salt
0 Ω
without salt
4850 Ω ± 5%
(at 25ºC)
1205 Ω ± 5%
(at 60ºC)
210 Ω ± 8%
OK
7750 Ω ± 8%
OK
6K Ω ± 8%
OK
3800 Ω ± 8%
connected in series
50 Ω ± 8%
start winding
180 Ω ± 8%
auxiliary winding
180 Ω ± 8%
OK

Advertisement

Table of Contents
loading

This manual is also suitable for:

DivaDiva bigEdw 2503-lcd

Table of Contents