Checking The Efficiency Of The Components; Measurement Points On The Board Wiring Connector - Electrolux Diva Service Manual

Hide thumbs Also See for Diva:
Table of Contents

Advertisement

14 Checking the efficiency of the components

In order to facilitate the control procedure for the components to be tested, a TEST PROCEDURE has been
created which indicates the point to which the probes of the tester should be applied and the correct
theoretical value for each component tested.
Remove the door and detach all the connectors from the main board.
Connect the probes of the tester to the appropriate points on the connector. Compare the ohmic reading
with the theoretical value.
Care should be taken relative to the position of connector "A1" - "A2": if this connector is
replaced in the incorrect position (back-to-front), the appliance will not function. The board will
not accept any commands since the power supply will be disconnected.

14.1 Measurement points on the board wiring connector

LIST OF COMPONENTS
* POWER CABLE &
(PU) - ON/OFF SWITCH
(RR) - HEATING ELEMENT +
(TS) - SAFETY THERMOSTAT
(PR) - LEVEL PRESSURE SWITCH
(PA) - ANTI-FLOODING PRESSURE SWITCH
(IP) - DOOR MICROSWITCH
(DD/DB) - INTEGRATED DISPENSER
(SB) - RINSE-AID SENSOR
(SS) - SALT SENSOR
(ST) - TEMPERATURE SENSOR
(GT) - TACHYMETRIC SENSOR
(MV) - FAN MOTOR
(ER) - REGENERATION SOLENOID
(EC) - FILL SOLENOID +
(AA) - ANTI-FLOODING DEVICE
(PL) - WASH MOTOR
(PS) - DRAIN MOTOR
N.B.: - *) = Measurement points L and N refer to the pins of the plug fitted to the power cable
SOI/TD PR
PROBE CONTACTS
L
B1
N
A2
A1
C5
B1
C5
C1
A2
B2
D1
D5
D7
F3
F4
F1
F2
G5
G6
E1
E2
D1
D3
D1
C9
D1
C7
C11
C3
To the two motor
wires (blue) / (red)
C11
C1
34/35
CORRECT VALUES
0 Ω
with ON/OFF key pressed
0 Ω
connected in series
25 Ω ± 8%
(2100W)
INFINITE
on "EMPTY" (1-2)
0 Ω
on "FULL" (1-3)
INFINITE
on "EMPTY" (1-2)
0 Ω
on "FULL" (1-3)
0 Ω
Door closed
1.500 Ω ± 8%
INFINITE
with Rinse-aid
0 Ω
without Rinse-aid
INFINITE
with salt
0 Ω
without salt
4850 Ω ± 5%
(at 25ºC)
1205 Ω ± 5%
(at 60ºC)
210 Ω ± 8%
7750 Ω ± 8%
6 KΩ ± 8%
3.800 Ω ± 8%
connected in series
50 Ω ± 8%
start-up winding
180 Ω ± 8%
auxiliary winding
180 Ω ± 8%
NOTES
OK
OK
OK
OK
OK
.
599 35 90-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Diva_edw1100

Table of Contents