Checking The Efficiency Of The Components; List Of Components - Electrolux EDW 2000 DIVA Service Manual

Dishwasher with electronic control
Table of Contents

Advertisement

2.3 CHECKING THE EFFICIENCY OF THE COMPONENTS

In order to facilitate the control procedure for the components to be tested, a TEST PROCEDURE has been
created which indicates the point to which the probes of the tester should be applied and the correct
theoretical value for each component tested.
Remove the door and detach all the connectors from the main board.
Connect the probes of the tester to the appropriate points on the connector. Compare the ohmic reading
with the theoretical value.
Care should be taken relative to the position of connector "A1-A2": f this connector is replaced
in the incorrect position (back-to-front), the appliance will not function since the power supply will
be disconnected.
Measurements points on the board wiring connectors:

LIST OF COMPONENTS

*) POWER CABLE &
(PU) – ON/OFF SWITCH
(RR) - HEATING ELEMENT +
(TS) - SAFETY THERMOSTAT
(PR) - LEVEL PRESSURE SWITCH
(PA) - ANTI-FLOODING PRESSURE
SWITCH
(IP) - DOOR MICROSWITCH
(DD/DB) - INTEGRATED DISPENSER
(SB) - RINSE-AID SENSOR
(SS) - SALT SENSOR
(ST) - TEMPERATURE SENSOR
(GT) - TACOMETER SENSOR
(MV) - FAN MOTOR
(ER) - REGENERATION SOLENOID
(EC) - FILL SOLENOID +
(AA) - ANTI-FLOODING DEVICE
(PL) - WASH MOTOR
(PS) - DRAIN MOTOR
Note: - *) = Measurement points L and N refer to the pins of the plug fitted to the power cable.
PROBE
CORRECT VALUES
CONTACTS
L
B1
N
A2
A1
C5
B1
C5
C1
A2
B2
D1
D5
D7
F3
F4
F1
F2
G5
G6
E1
E2
C11
D3
C11
C9
C11
C7
C11
C3
To the 2 motor wires
(bl) / (ro)
C11
C1
0 Ω
with ON/OFF button
held down
0 Ω
connected in series
25 Ω ± 8%
(2100W)
INFINITE
on "EMPTY" (1-2)
0 Ω
on "FULL" (1-3)
INFINITE
on "EMPTY" (1-2)
0 Ω
on "FULL" (1-3)
0 Ω
Door closed
1.500 Ω ± 8%
OK
INFINITE
with Rinse-aid
0 Ω
without Rinse-aid
INFINITE
with salt
0 Ω
without salt
4850 Ω ± 5%
(a 25ºC)
1205 Ω ± 5%
(a 60ºC)
210 Ω ± 8%
OK
7750 Ω ± 8%
OK
6 KΩ ± 8%
OK
3.800 Ω ± 8%
connected in series
50 Ω ± 8%
start-up winding
180 Ω ± 8%
auxiliary winding
180 Ω ± 8%
OK
NOTES

Advertisement

Table of Contents
loading

Table of Contents