CHECKING THE EFFICIENCY OF THE COMPONENTS
In order to facilitate checking of the efficiency of the component to be tested, a special CONTROL
PROCEDURE has been created. The contacts to which the tester should be applied and the correct
resistance for each component are shown in the table below.
After detaching the modular wiring connector fitted to the bottom of the appliance, measure the resistance
to verify the efficiency of the components fitted to the dishwasher.
TRADITIONAL DISHWASHERS (ELECTROMECHANICAL TIMER)
PROCEDURE: Apply the probes of the tester to the points indicated and measure the resistance.
COMPONENT
MOTOR
( Drain )
MOTOR
( Washing )
REGENERATION
SOLENOID
FILL SOLENOID AND
ANTI-FLOODING DEVICE
RESET
SOLENOID
N.B.
If the resistance measured across contacts 1 - 8 and 3 - 8 is the same
(28 Ω Ω Ω Ω approx.), this means that the capacitor is short-circuited.
KEY:
ar = orange
ma = brown
The remaining components can be tested in the same way or directly on the components themselves.
The correct values are listed below:
COMPONENT
DOOR MICROSWITCH
PRESSURE SWITCH
HEATING ELEMENT AND
SAFETY THERMOSTAT
FAN MOTOR
INTEGRATED DETERGENT
DISPENSER
TEMPERATURE CONTROL
THERMOSTAT(S)
SALT SENSOR
RINSE-AID SENSOR

TROUBLESHOOTING

TESTER PROBES
CONNECTION /
COLOUR
1 - 8
Grey - Blue
Brown - Blue
3 - 8
6 - 7
Black - Light blue
5 - 9
Purple -Pink
4 - 10
White - Grey
bi = white
bl = blue
ne = black
ro = pink
CORRECT VALUE
Door closed
0 W
Empty (1-2)
INFINITE
Full (1-3)
0 W
2300 W
25 W ± 8%
720 W ± 8%
1300 W ± 8%
Open
INFINITE
Closed
0 W
With salt
INFINITE
Without salt
0 W
With rinse-aid
INFINITE
Without rinse-aid
0 W
CORRECT VALUE
73 Ω Ω Ω Ω ± 7%
48 Ω Ω Ω Ω ± 7%
5200 Ω Ω Ω Ω ± 8%
3950 Ω Ω Ω Ω ± 8%
5200 Ω Ω Ω Ω ± 8%
ce = light blue
gr = grey
vi = purple