System Health Monitor; System Fan Monitor - Supermicro AS-1041M-82 User Manual

Supermicro as-1041m-82 servers: user guide
Table of Contents

Advertisement

VT-UTF8 Combo Key Support
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/
VT100 terminals.
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information. Op-
tions are No Delay, 1 sec, 2 secs and 4 secs.

System Health Monitor

CPU Overheat Temperature
Use the "+" and "-" keys to set the CPU temperature threshold to between 65
o
and 90
C. When this threshold is exceeded, the overheat LED on the chas-
sis will light up and an alarm will sound. The LED and alarm will turn off once
the CPU temperature has dropped to 5 degrees below the threshold set. The
o
default setting is 72
C.
Other items in the submenu are systems monitor displays for the following
information:
CPU1 Temperature, CPU2 Temperature, CPU3 Temperature, CPU4 Tempera-
ture, (for 4U systems), System Temperature, CPU1 Vcore, CPU2 Vcore, CPU3
Vcore, CPU4 Vcore (for 4U systems), 3.3V Vcc, +5Vin, +12Vin, 5V standby and
battery voltage.

System Fan Monitor

Fan Speed Control
This feature allows the user to determine how the system will control the speed of
the onboard fans. Select "Workstation" if your system is used as a Workstation.
Select "Server" if your system is used as a Server. Select "Disable" to disable
the fan speed control function to allow the onboard fans to continuously run at
full speed (12V). The options are 1) Disabled (Full Speed) 2) Optimized for
Server and 3) Optimized for Workstation.
FAN1 Speed through FAN9 Speed
The speeds of the onboard fans (in rpm) are displayed here.
7-15
Chapter 7: BIOS
o

Advertisement

Table of Contents
loading

This manual is also suitable for:

As1041m-t2

Table of Contents