  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments PXI-8119 at our website:...
  • Page 2 NI PXI-8119 User Manual NI PXI-8119 User Manual July 2012 373721A-01 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments Web site at and enter ni.com/info the Info Code feedback ©...
  • Page 4 Warranty The NI PXI-8119 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period.
  • Page 5 CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY...
  • Page 6 Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules.
  • Page 7: Table Of Contents

    Introduction Benefits of PXI ......................1-1 NI PXI-8119 ........................1-2 Description ......................1-2 Functional Overview ..................1-3 NI PXI-8119 Functional Description ..........1-3 National Instruments Software ..................1-5 Chapter 2 Installation and Configuration Installing the NI PXI-8119 ....................2-1 How to Remove the Controller from the PXI Chassis ........2-4 BIOS Setup Utility......................2-4...
  • Page 8 Universal Serial Bus..................3-9 Trigger......................3-10 GPIB (IEEE 488.2) ..................3-11 ExpressCard/34 Slot..................3-13 Front Panel Features ...................... 3-15 Data Storage ........................3-15 NI PXI-8119 User Manual viii ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 Software Driver Installation...................4-4 Upgrade Information......................4-5 PXI Configuration......................4-6 Chapter 5 Troubleshooting Appendix A Specifications Appendix B Technical Support and Professional Services Glossary Index © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10: About This Manual

    National Instruments PXI-8119 embedded computer kit. How to Use the Documentation Set Begin by reading the NI PXI-8119 Installation Guide, a brief quick-start guide that describes how to install and get started with your controller. This manual, the NI PXI-8119 User Manual, contains more details about changing the installation or configuration from the defaults and using the hardware.
  • Page 11: Related Documentation

    Universal Serial Bus (USB) Specification, Revision 2.0 • IEEE Std 488.1-2003, IEEE Standard for Higher Performance Protocol for the Standard Digital Interface for Programmable Instrumentation NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12: Introduction

    Introduction This chapter provides overview information for PXI and the NI PXI-8119 embedded controller. Benefits of PXI The PXI (PCI eXtensions for Instrumentation) industry standard, an open specification governed by the PXI Systems Alliance (PXISA), defines a compact modular PC platform for test, measurement, and control systems.
  • Page 13: Ni Pxi-8119

    Chapter 1 Introduction NI PXI-8119 Description The NI PXI-8119 PXI/CompactPCI embedded computer is a high-performance PXI/CompactPCI system controller. The NI PXI-8119 controller integrates standard I/O features in a single unit by using state-of-the-art packaging. Combining an NI PXI-8119 embedded controller with a PXI-compatible chassis, such as the NI PXI-1042, results in a fully PC-compatible computer in a compact, rugged package.
  • Page 14: Functional Overview

    NI PXI-8119 embedded computer. NI PXI-8119 Functional Description The NI PXI-8119 is a modular PC in a PXI 3U-size form factor. Figure 1-1 is a functional block diagram of the NI PXI-8119. Following the diagram is a description of each logic block shown.
  • Page 15 Chapter 1 Introduction The NI PXI-8119 consists of the following logic blocks on the CPU module and the I/O (daughter card) module. The CPU module has the following logic blocks: ® ™ • The processor is an Intel Core i7-3610QE Processor (6 Mb cache, 2.3 GHz).
  • Page 16: National Instruments Software

    Chapter 1 Introduction National Instruments Software National Instruments has developed several software tools you can use with the NI PXI-8119. National Instruments’ hardware and software work together to help you make the most of your PXI system. The LabVIEW, Measurement Studio, ™...
  • Page 17 NI-Sync. For more information visit ni.com/pxi NI-VISA is the National Instruments implementation of the VISA specification. VISA is a uniform API for communicating and controlling USB, Serial, GPIB, PXI, VXI, and various other types of instruments. This API aids in the creation of portable applications and instrument drivers.
  • Page 18: Installation And Configuration

    This section contains general installation instructions for the NI PXI-8119. Consult your PXI chassis user manual for specific instructions and warnings. Plug in your chassis before installing the NI PXI-8119. The power cord grounds the chassis and protects it from electrical damage while you install the module.
  • Page 19 1 Protective Screw Cap (4x) Figure 2-1. Removing Protective Screw Caps Make sure the injector/ejector handle is in its downward position. Align the NI PXI-8119 with the card guides on the top and bottom of the system controller slot. Caution Do not raise the injector/ejector handle as you insert the NI PXI-8119.
  • Page 20 What if the NI PXI-8119 does not boot? section of Chapter 5, Troubleshooting. Figure 2-2 shows an NI PXI-8119 installed in the system controller slot of a National Instruments NI PXI-1042 chassis. 1 NI PXI-1042 Chassis 3 Injector/Ejector Rail 2 NI PXI-8119 Controller Figure 2-2.
  • Page 21: How To Remove The Controller From The Pxi Chassis

    The BIOS setup program includes menus for configuring settings and enabling NI PXI-8119 controller features. Most users do not need to use the BIOS setup program, as the NI PXI-8119 controller ships with default settings that work well for most configurations.
  • Page 22: Main Setup Menu

    The Main setup menu reports the following configuration information: • BIOS Version and Build Date—These values indicate the version of the NI PXI-8119 controller BIOS and the date on which the BIOS was built. • Embedded Firmware Version—This value helps identify the built-in hardware capabilities.
  • Page 23: Advanced Setup Menu

    • Power/Wake Configuration—Use this setting to access the Power/Wake Configuration submenu. Refer to the Power/Wake Configuration Submenu section for more information. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24: Sata Configuration Submenu

    Real Time system. To achieve maximum possible Turbo Boost frequencies, also enable the C-States setting. © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25: Video Configuration Submenu

    Reserved Buses, Reserved Memory, and Reserved I/O settings. The default value for this setting is Enabled. If this setting is NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 26: Usb Configuration Submenu

    When set to Auto, a root port is granted 100 ms, and for a hub port, the © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 27: Serial/Parallel Port Configuration Submenu

    Change Settings—This setting changes the base address and interrupt request level (IRQ) information for the onboard serial port. The default value is Auto. NI PXI-8119 User Manual 2-10 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 28: Parallel Port Configuration Submenu

    IP address and other TCP/IP settings to their factory defaults during LabVIEW RT startup. The default is Use Switch Setting. © National Instruments 2-11 NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29: Labview Rt Configuration Overrides Submenu

    • Boot Option Priorities—These settings specify the order in which the BIOS checks for bootable devices, including the local hard disk drive, NI PXI-8119 User Manual 2-12 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Boot Settings Configuration Submenu

    • Bootup NumLock State—This setting specifies the power-on state of the keyboard NumLock setting. The default value is On. © National Instruments 2-13 NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 31: Hard Drive Bbs Priorities Submenu

    BIOS setup program. In the BIOS setup program, the User will have Administrator rights. By default, no password is specified. NI PXI-8119 User Manual 2-14 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32: Save & Exit Menu

    If BIOS setup options have been changed and saved, a reboot will be required and the boot override selection will not be valid. © National Instruments 2-15 NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 33: Bios Diagnostic Utilities

    Note If the memory test fails, the controller is not permitted to boot, and the user is instructed to turn off the controller and replace the memory. NI PXI-8119 User Manual 2-16 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 34: System Cmos

    Chapter 2 Installation and Configuration System CMOS The NI PXI-8119 contains memory backed up by a battery to store BIOS configuration information. Complete the following steps to clear the CMOS contents: Power off the chassis. Remove the controller from the chassis.
  • Page 35: Labview Rt Installation

    Click on the appropriate PXI controller entry to access the Network Settings tab in the right pane view. (Optional) Enter a name for the RT target in the Name text box. NI PXI-8119 User Manual 2-18 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 36 Refer to the RT Getting Started Guide available on your host computer for more information about setting up your RT target. © National Instruments 2-19 NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 37: Labview Rt Configuration Switches

    If you are not using LabVIEW RT, these switches should remain in the OFF position. The controller reads these switches only after a system reset. The NI PXI-8119 controller includes the following LabVIEW RT configuration switches: •...
  • Page 38 3 Switch 3—Disable Startup VI 2 Switch 2—Boot Safe Mode 4 Switch 4—Reset IP Address Figure 2-4. LabVIEW RT Configuration Switches © National Instruments 2-21 NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 39: Drivers And Software

    PXI Features PXI Trigger Connectivity The SMB connector on the NI PXI-8119 front panel can connect to or from any PXI backplane trigger line. A trigger allocation process is needed to prevent two resources from connecting to the same trigger line, resulting in the trigger being double-driven and possibly damaging the hardware.
  • Page 40: Basic Pxi System Configuration

    PXI specification at www.pxisa.org Upgrading RAM You can change the amount of installed RAM on the NI PXI-8119 by upgrading the SO-DIMM. National Instruments offers the following SO-DIMM for use with the NI PXI-8119 controller.
  • Page 41: Hard Drive Recovery

    Note National Instruments has tested and verified that the DDR3 SO-DIMMs we sell work with the NI PXI-8119. We recommend you purchase your DDR3 SO-DIMM modules from National Instruments. Other off-the-shelf DDR3 SO-DIMM modules are not guaranteed to work properly.
  • Page 42: Installing An Os

    Recovering the OS erases the contents of your hard disk. Back up any files you want Note to keep. Installing an OS NI PXI-8119 controllers include a preinstalled OS. In some cases, you may want to install a different OS. When doing so, consider the following guidelines. Installing from a USB CD/DVD-ROM The NI PXI-8119 supports the installation of Windows 7 or Windows XP from a USB CD/DVD-ROM.
  • Page 43: Removing An Expresscard

    Slide the card out of the slot. To avoid data loss and other potential issues, stop communication with your Caution ExpressCard device before removing it from the NI PXI-8119. In Windows, use the Safely Remove Hardware tool to safely stop the ExpressCard. Power Budgeting The NI PXI-8119 is a high power, high performance controller.
  • Page 44: I/O Information

    I/O Information Front Panel Connectors Table 3-1 lists various peripherals and their corresponding NI PXI-8119 external connectors, bus interfaces, and functions. Table 3-1. NI PXI-8119 Peripherals Overview Peripheral External Connector Description Video DisplayPort Intel Extreme Graphics controller Serial COM1 16550 RS-232 serial port...
  • Page 45: Front Panel

    1.285 in. (32.65 mm) 1.070 in. (27.19 mm) NI PXI-8119 Embedded Controller .000 in. (0 mm) Figure 3-1. NI PXI-8119 Front Panel Layout and Dimensions NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 46: Displayport

    Chapter 3 I/O Information DisplayPort Figure 3-2 shows the location and pinouts for the DisplayPort connectors on the NI PXI-8119. Table 3-2 lists and describes the DisplayPort connector signals. NI PXI-8119 Embedded Controller Figure 3-2. DisplayPort Connector Location and Pinout Table 3-2.
  • Page 47 Table 3-2. DisplayPort Connector Signals (Continued) Signal Name ML_Lane3(p) ML_Lane3(n) CONFIG1 CONFIG2 AUX CH (p) AUX CH (n) Hot Plug Detect Return DP_PWR NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 48: Com1

    Chapter 3 I/O Information COM1 Figure 3-3 shows the location and pinouts for the COM1 connector on the NI PXI-8119. Table 3-3 lists and describes the COM1 connector signal. COM1 NI PXI-8119 Embedded Controller Figure 3-3. COM1 Connector Location and Pinout Table 3-3.
  • Page 49: Ethernet

    Chapter 3 I/O Information Ethernet Figure 3-4 shows the location and pinouts for the Ethernet connector on the NI PXI-8119. Table 3-4 lists and describes the Ethernet connector signals. Ethernet NI PXI-8119 Embedded Controller Figure 3-4. Ethernet Connector Location and Pinout Table 3-4.
  • Page 50: Parallel Port

    1000 Mbit/sec data rate is selected. Parallel Port Figure 3-5 shows the location and pinouts for the IEEE 1284 (parallel) connector on the NI PXI-8119. Table 3-6 lists and describes the IEEE 1284 connector signals. Parallel port adapter cables are available from National Instruments, part number 777169-01.
  • Page 51 Select Input AUTOFD# Auto Line Feed +5 V 19–35 Ground Not Connected Note: The pound symbol (#) indicates an active low signal. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 52: Universal Serial Bus

    Universal Serial Bus Figure 3-6 shows the location and pinouts for the Universal Serial Bus (USB) connector on the NI PXI-8119. Each controller has six USB ports on the front panel. Table 3-7 lists and describes the USB connector signals.
  • Page 53: Trigger

    The TRIG connector is the software-controlled trigger connection for routing PXI triggers to or from the backplane trigger bus. Figure 3-8 shows the TRIG connector location on the NI PXI-8119. Table 3-8 lists and describes the trigger connector signals. NI PXI-8119 Embedded Controller Figure 3-8.
  • Page 54: Gpib (Ieee 488.2)

    2 (Shield) Ground GPIB (IEEE 488.2) Figure 3-9 shows the location and pinouts for the GPIB connector on the NI PXI-8119. Table 3-9 lists and describes the GPIB connector signals. National Instruments provides a GPIB mating connector, part number 183285-0R2. GPIB...
  • Page 55 Data Bit 7 DIO8# Data Bit 8 REN# Remote Enable 18–25 Logic Ground Note: The pound symbol (#) indicates an active low signal. NI PXI-8119 User Manual 3-12 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 56: Expresscard/34 Slot

    Chapter 3 I/O Information ExpressCard/34 Slot The NI PXI-8119 controller is equipped with an ExpressCard/34 slot on the front panel, which provides I/O expansion and options for removable storage, Ethernet, and a variety of other I/O. Figure 3-10 shows the location and pinouts for the ExpressCard/34 slot on the NI PXI-8119.
  • Page 57 PETn0 PE Data Transmit – PETp0 PE Data Transmit + Ground Note: The pound symbol (#) indicates an active low signal. NI PXI-8119 User Manual 3-14 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 58: Front Panel Features

    The USER2 LED is a bi-color green/yellow LED. You can define the USER2 LED to meet the needs of your LabVIEW application. Data Storage The NI PXI-8119 has the following data storage features: • 2.5 in. SATA notebook internal hard drive •...
  • Page 59: Common Configuration Questions

    How do I check the configuration of the memory, hard drive, time/date, and so on? You can view these parameters in the BIOS setup. To enter the BIOS setup, reboot the NI PXI-8119 and press <Delete> during the memory tests. Refer to the Accessing BIOS Setup Utility...
  • Page 60 There are some limitations when booting from a USB device. Windows XP can be installed from a USB CD/DVD-ROM, but earlier versions of Windows cannot. The NI PXI-8119 BIOS configures the USB devices so that they will work in a DOS environment.
  • Page 61: Cables And Connections

    How do I plug both a PS/2 mouse and PS/2 keyboard into the controller? The NI PXI-8119 has no PS/2 connector, and you need to use a USB Y-splitter cable as shown in Figure 4-1, or a similar device, to connect both a PS/2 mouse and PS/2 keyboard.
  • Page 62: Software Driver Installation

    GPIB driver in the Device Manager. If you need more assistance, refer ni.com/support/install How do I install software from a CD? The compact size of the NI PXI-8119 does not allow for an integrated CD/DVD-ROM drive. You have the following options: •...
  • Page 63: Upgrade Information

    Common Configuration Questions Upgrade Information How do I upgrade system memory? You can change the amount of installed RAM on the NI PXI-8119 by upgrading the DDR3 SO-DIMM. To upgrade the RAM, remove the NI PXI-8119 from the PXI chassis.
  • Page 64: Pxi Configuration

    Chapter 4 Common Configuration Questions 1 DDR3 SO-DIMM Module 2 DDR3 SO-DIMM Socket Figure 4-2. Installing a DDR3 SO-DIMM in an NI PXI-8119 Controller How do I flash a new BIOS? You can download the new BIOS from ftp.ni.com/support/pxi For more information, refer to KnowledgeBase 2GIGKD0Z, Determining and Upgrading PXI and VXI Embedded Controller BIOS Versions.
  • Page 65: Troubleshooting

    This chapter answers common troubleshooting questions you may have when using the NI PXI-8119 embedded computer. What if the NI PXI-8119 does not boot? Several problems can cause a controller not to boot. Here are some things to look for and possible solutions.
  • Page 66 Select Save and Exit Setup. As an alternative method, complete the following steps: Power off the chassis. Remove the controller from the chassis. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 67 SW1 switch location is shown in Figure 5-1. Reinstall the controller in the chassis. 1 Push-Button Switch S1 Figure 5-1. Clearing the CMOS Contents © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 68 Specifications This appendix lists the electrical, mechanical, and environmental specifications of the NI PXI-8119 embedded controller. Features NI PXI-8119 ® ™ Intel Core i7 3610QE (2.3 GHz quad-core processor) On-die L2 cache 6 MB Single-Channel DDR3 RAM, 4 GB Standard...
  • Page 69 (at 25 °C ambient temperature) Pollution Degree ........2 Indoor use only. Caution Clean the NI PXI-8119 with a soft nonmetallic brush. Make sure that the device is completely dry and free from contaminants before returning it to service. NI PXI-8119 User Manual ni.com...
  • Page 70 IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) For chassis that are not available in the online catalog at , contact National Instruments for supported operating ni.com temperatures. Processor should not throttle CPU frequency under reasonable, worst case processor work loads in high operating temperatures.
  • Page 71 UL 61010-1, CSA 61010-1 For UL and other safety certifications, refer to the product label or the Online Note Product Certification section. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 72 DoC for this product, visit , search by model ni.com/certification number or product line, and click the appropriate link in the Certification column. © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 73 Battery Directive 2006/66/EC about Batteries and Accumulators and Waste Batteries and Accumulators, visit ni.com/environment/batterydirective National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 74 • System Integration—If you have time constraints, limited in-house technical resources, or other project challenges, National Instruments © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 75 You also can visit the Worldwide Offices section of ni.com/niglobal to access the branch office Web sites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 76 PC or compatible computer. BIOS functions embody the basic operations needed for successful use of the computer’s hardware resources. © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 77 It was developed by an industry consortium, the Digital Display Working Group (DDWG). Extended Capabilities Parallel. EEPROM Electronically Erasable Programmable Read Only Memory. Electromagnetic Compatibility. Electromagnetic interference. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 78 A means for a device to request service from another device. interrupt level The relative priority at which a device can interrupt. © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 79 Mean time between failure. NI-488 or NI-488.2 The National Instruments software for GPIB systems. NI-DAQ The National Instruments software for data acquisition instruments. NI-VISA The National Instruments implementation of the VISA standard—An interface-independent software that provides a unified programming interface for VXI, GPIB, and serial instruments.
  • Page 80 SPI Bus Serial Peripheral Interface—A standard for controlling most any digital electronics that accept a clocked serial stream of bits. © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 81 Glossary Universal Serial Bus. Volts. Video Graphics Array—The minimum video display standard for all PCs. Watts. NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 82 SATA Configuration menu, 2-7 boot options, 4-1 Save & Exit menu, 2-15 cables and connections, 4-3 chassis configuration, 2-22 driver installation, 4-4 © National Instruments NI PXI-8119 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 83 PXI trigger, 3-1 DRIVE LED, 3-15 serial, 3-1, 3-5 drivers trigger, 3-10 directory, 2-22 USB, 3-1, 3-9 installation video, 3-1, 3-3 NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 84 BBS priorities menu, 2-14 LabWindows/CVI, 1-5 help, technical support, B-1 LEDs, front panel LEDs, 3-15, 4-1 Linux support, 1-6 LPT cable, connecting to NI PXI-8119, 4-3 IEEE 488.2, 3-11 images directory, 2-22 installation Main Setup menu, 2-5 See also configuration...
  • Page 85 PXI chassis, 2-1 figure, 2-3 logic blocks, 1-4 peripheral expansion overview (table), 3-1 PXI trigger connectivity, 2-22 removing from a PXI chassis, 2-4 NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 86 Serial/Parallel Port Configuration menu, 2-10 troubleshooting Parallel Port menu, 2-11 CMOS reset, 5-2 Serial Port menu, 2-10 controller does not boot, 5-1 setting up the NI PXI-8119 BIOS, 2-4 damaged module, 5-2 shock and vibration specifications, A-4 NI resources, B-1 software video display, 5-2...
  • Page 87 Web resources, B-1 WEEE information, A-6 Y-splitter cable (figure), 4-3 using mouse and keyboard without, 4-3 using with PS/2 mouse and keyboard, 2-3 NI PXI-8119 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...

Table of Contents