Display
17
18
17 . Weekly programming
18 . Operation and diagnostics
ABCDE...
19 . Room control and management of peripherals
4
ABCDEFGHIL123456
Schedule programming
Day of the week (Mon......Sun)
Zone indication relating to the
display/setting process of the Hea-
ting schedule programming (zone
1 and zone )
Date and time
Heating schedule programming
activated
Digits indicating:
boiler status and temperature
indication
menu settings
error code signals
Internal temperature displayed
(with bus device optional)
External temperature displayed
(with external sensor optional)
Reset button request
Technical assistance request
Digital pressure gauge
Flame detected with indication of
power used or indication of opera-
tion shutdown
Heating operation and indication
of the set temperature level
Scrolling text displaying operation
as information
AUTO function activated
(Temperature regulation
activated) with indication of any
internal (BUS) or external sensors
connected.
Display Info menu
Clip-in solar connected (optional)
Constant = solar clip-in connected
Flashing = use of solar energy
activated
Initial operating and filling procedures.
Check the water pressure on the display regularly and make sure
that the figure is between 0.6 and1.5 bar when the system is cold.
If the pressure is just under the minimum value the display will
request a the boiler be refilled.
To re-pressurise the boiler, it will be necessary to connect
the silver flexible hose supplied to the two isolating points
underneath the boiler, once the hose is connected, open up both
of the black quarter turn handles, once the pressure reads 1.5 bar
on the display, close both handles and disconnect the hose .
If the pressure drops very frequently, there may be a water leak
at some point in the system. If this is the case please contact your
installer and ask them to check it.
Ignition procedure
Press the ON/OFF button on the control panel to switch on the boiler.
The display shows:
Summer
The operating mode will be indicated by the three figures marked
out on the diagram above.
The first figure indicates the operating mode:
0 XX
- Stand-by, the text on the display show the
operating mode selected ( winter or summer)
C XX - Central heating request
c XX - Heating post-circulation
d XX - Cylinder Heat Request
H XX - Hot water post-circulation
F XX - Circulation pump anti-freeze protection enabled
- burner anti-freeze protection enabled
The second and third figures indicate:
- the flow temperature when no heating requests have been made
- the flow temperature in central heating mode
- the temperature of the hot water in domestic hot water mode
- the flow temperature in anti-freeze mode.