HIKVISION DS-K3B801S Series Quick Start Manual
HIKVISION DS-K3B801S Series Quick Start Manual

HIKVISION DS-K3B801S Series Quick Start Manual

Swing barrier

Advertisement

Quick Links

DS-K3B801SX Series Swing Barrier
Quick Start Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-K3B801S Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION DS-K3B801S Series

  • Page 1 DS-K3B801SX Series Swing Barrier Quick Start Guide...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3B801SX Series Swing Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3B801SX Series Swing Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3B801SX Series Swing Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
  • Page 7 DS-K3B801SX Series Swing Barrier Quick Start Guide Do not ingest battery, Chemical Burn Hazard. ● This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children.
  • Page 8 DS-K3B801SX Series Swing Barrier Quick Start Guide Please keep all wrappers after unpack them for future use. In case of any failure occurred, you ● need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.
  • Page 9 DS-K3B801SX Series Swing Barrier Quick Start Guide Available Models Product Name Model Description Swing Barrier DS-K3B801SX-L Left Pedestal DS-K3B801SX-M Middle Pedestal DS-K3B801SX-R Right Pedestal Scan the QR code to get User Manual of Swing Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable.
  • Page 10: Table Of Contents

    DS-K3B801SX Series Swing Barrier Quick Start Guide Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................2 Chapter 2 System Wiring ......................3 Chapter 3 Installation ......................... 8 3.1 Disassemble before Installation ..................... 8 3.2 Install Pedestals ........................16 Chapter 4 Disassemble before Maintenance ................
  • Page 11 DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.8 Barrier Control Wiring ....................48 5.6.9 Alarm Output Wiring ....................50 5.6.10 Exit Button Wiring ..................... 50 Chapter 6 Device Settings ......................52 6.1 Set Study Mode ........................52 6.2 Pair Keyfob (Optional) ......................53 6.3 Initialize Device ........................
  • Page 12: Chapter 1 Overview

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction The swing barrier with two barriers and 24 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integrated with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc.
  • Page 13: Main Features

    DS-K3B801SX Series Swing Barrier Quick Start Guide 1.2 Main Features 32-bit high-speed processor ● TCP/IP network communication ● The communication data is specially encrypted to relieve the concern of privacy leak. Permissions validation and anti-tailgating ● Remaining open/closed mode selectable ●...
  • Page 14: Chapter 2 System Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 2 System Wiring The preparation before installation and wiring. Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+100 mm.
  • Page 15 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 2-1 Hole Position Diagram 4. Bury cables. Each lane buries 1 network cable and 1 high voltage cable. For details, see the system wiring diagram below.
  • Page 16 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 2-2 System Wiring Diagram (General Wiring) Note The supplied interconnecting cable length is 5.5 m. ● The suggested inner diameter of the low voltage conduit is larger than 30 mm. ● If you want to bury both of the AC power cord and the low voltage cable at the entrance, the ●...
  • Page 17 DS-K3B801SX Series Swing Barrier Quick Start Guide The external AC power cord should be double-insulated. ● The network cable must be CAT5e or the network cable has better performance. And the ● suggested network cable length should be less than 100 m. Figure 2-3 Wire Face Recognition Terminal Note The supplied interconnecting cable length is 5.5 m.
  • Page 18 DS-K3B801SX Series Swing Barrier Quick Start Guide The face recognition terminal installed on the left pedestal will gain power from the 12 V ● power supply, which should connect to the electric supply. The suggested inner diameter of the low voltage conduit is larger than 30 mm. ●...
  • Page 19: Chapter 3 Installation

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble before Installation Before installation, you should disassemble the pedestal and remove some screws. Before You Start Keep the disassembled components and screws. ● You should prepare the following tools to disassemble the pedestal: 1. Pedestal Key (supplied); 2. ●...
  • Page 20 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-1 Lock Position 2. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 25) at the top of the device.
  • Page 21 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-2 M5×25 Screws 3. Remove the components along the arrow direction carefully.
  • Page 22 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-3 Remove Components 4. Loosen the wing bolt (M4 × 10) at the front and back of the pedestal, and remove the front and back base covers along the arrow direction.
  • Page 23 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-4 Loosen Wing Bolt Figure 3-5 Remove Base Cover You can start installing the expansion screws to secure the device on the installation surface. 5. Remove the motor bottom cover.
  • Page 24 DS-K3B801SX Series Swing Barrier Quick Start Guide 1) Pull or push the barrier to the closed position. 2) Use the Allen wretch (2.5 mm) to loosen the 4 screws (M4 × 8) on the motor bottom cover. Figure 3-6 M4×8 Screw 3) Pull or push the barrier to the open position, and remove the motor bottom cover.
  • Page 25 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-7 Remove Motor Bottom Cover Note If dissembling the middle pedestal, you should dissemble two motor bottom covers. 6. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 12) at the front or back of the pedestal base and remove the side base cover slowly.
  • Page 26 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-8 Remove Side Base Cover Note If dissembling the middle pedestal, you should dissemble two side base covers. 7. Disassemble the two protective sheets at the bottom for wiring, and you can start wiring the interconnecting cable.
  • Page 27: Install Pedestals

    DS-K3B801SX Series Swing Barrier Quick Start Guide 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note The device should be installed on the concrete surface or other non-flammable surfaces. ●...
  • Page 28 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 3-11 Installation Footprint 5. After installation, assemble the components and screws back to the pedestal in reverse order (except for protective sheets).
  • Page 29: Chapter 4 Disassemble Before Maintenance

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 4 Disassemble before Maintenance Before maintaining the inner components, you should disassemble the pedestal and remove some screws. Note Keep the disassembled components and screws organized. ● You should prepare the following tools to disassemble the pedestal: 1. Pedestal Key (supplied); 2. ●...
  • Page 30 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-1 Lock Position 2. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 25) at the top of the device...
  • Page 31 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-2 M5×25 Screws Position 3. Remove the components along the arrow direction carefully.
  • Page 32: Disassemble Motor Bottom Cover

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-3 Remove Components 4.2 Disassemble Motor Bottom Cover After disassembling the motor bottom cover, you can maintain the lane control board and the barrier position control board. Steps 1. Pull or push the barrier to the closed position. 2.
  • Page 33 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-4 M4×8 Screws Position 3. Pull or push the barrier to the open position, and remove the motor bottom cover.
  • Page 34: Disassemble Side Base Cover

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-5 Remove Bottom Cover Note If dissembling the middle pedestal, you should dissemble two motor bottom covers. 4.3 Disassemble Side Base Cover After disassembling the side base cover, you can maintain the IR sending/receiving board. Steps 1.
  • Page 35 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-6 Lock Position 2. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 25) at the top of the device.
  • Page 36 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-7 M5×25 Screws Position 3. Remove the components along the arrow direction carefully.
  • Page 37 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-8 Remove Components 4. Use the Allen wretch (4 mm) to loosen the 2 screws (M5 × 12) at the front or back of the pedestal base and remove the side base cover slowly.
  • Page 38: Disassemble Top Cover

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-9 Remove Side Base Cover Note If dissembling the middle pedestal, you should dissemble two side base covers. 4.4 Disassemble Top Cover After disassembling the top cover, you can maintain the components at the top of the pedestal, the IR sending/receiving board and the IR adaptor for instance.
  • Page 39 DS-K3B801SX Series Swing Barrier Quick Start Guide 2. Move the front and back top covers along the arrow 1's direction for about 3 cm, and move them upwards to remove the front and back top covers. Figure 4-11 Remove Front and Back Top Cover 3.
  • Page 40 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-12 Top Captive Panel Screws 5. Remove the top cover along the arrow's direction.
  • Page 41 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 4-13 Remove Top Cover...
  • Page 42: Chapter 5 General Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 5 General Wiring 5.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system’s power supply.
  • Page 43 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-1 Components Diagram The picture displayed below describes the IR sending/receiving module and their corresponding number on the pedestal.
  • Page 44 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-2 IR Sending/Receiving Module Position Note If the turnstile contains two lanes, standing at the entrance position, the IR modules on the left pedestal are the IR sending modules. The IR modules on the right pedestal are the IR receiving modules.
  • Page 45: Wiring Electric Supply

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.2 Wiring Electric Supply Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch, while terminal PE should connect to a ground wire (yellow and green wire). Note The cable bare part should be no more than 8 mm.
  • Page 46: Wire Interconnecting Cable

    DS-K3B801SX Series Swing Barrier Quick Start Guide To avoid people injury and device damage, when testing, the ground resistance of the ● equipotential points should not be larger than 2 Ω。 Use the device in conjunction with an UPS. ● 5.3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication.
  • Page 47: Wire Network Switch

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-4 Connect Interconnecting Cable 5.4 Wire Network Switch Connect the network cable and the network switch. Steps Note The device do not support the PoE network switch. Connecting with the PoE network switch may damage the control board.
  • Page 48: Face Recognition Terminal Power Supply Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-5 Network Switch Position 2. Lead out 12 V power supply from the main switch and connect it to the network switch's power interface. 3. Connect the network cable with the network switch. 5.5 Face Recognition Terminal Power Supply Wiring You should wire the power supply terminal on the 12 V power supply component if you connect the turnstile to the face recognition terminal.
  • Page 49: Terminal Description

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-6 Face Recognition Terminal Power Supply Wiring Position 5.6 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work. 5.6.1 Main Control Board Terminal Description The main lane control board contains power supply interface, supercapacitor interface, brake interface, motor drive interface, light board interface, motor encoder interface, door open position...
  • Page 50: Sub Control Board Terminal Description

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-7 Main Control Board 5.6.2 Sub Control Board Terminal Description The sub lane control board contains power supply interface, supercapacitor interface, brake interface, motor drive interface, light board interface, motor encoder interface, door open position detection interface, debug port, lane communication interface, and interconnecting interface.
  • Page 51: Access Control Board Terminal Description

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.3 Access Control Board Terminal Description Figure 5-9 Access Control Board Table 5-1 Access Control Board Terminal Description Access Control Board Terminal Description Power Output 1 +12 V Power Output Grounding Wiegand Card Indicator of Card Reader Control Output (Invalid Card Reader 1 Output)
  • Page 52 DS-K3B801SX Series Swing Barrier Quick Start Guide Access Control Board Terminal Description Indicator of Card Reader Control Output (Valid Card Output) Card Reader Buzzer Control Output Wiegand Head Read Data Input Data1 Wiegand Head Read Data Input Data0 Grounding RS-485 Interface Grounding RS-485 B- Connect to Card Reader RS485-...
  • Page 53 DS-K3B801SX Series Swing Barrier Quick Start Guide Access Control Board Terminal Description Exit Button Door 2 Signal Input Grounding Door 1 Signal Input Door Lock (Relay) Door 1 Relay Output (Dry Contact) Door 2 Relay Output (Dry Contact) Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) COM1...
  • Page 54: Access Control Board Serial Port Id Description

    DS-K3B801SX Series Swing Barrier Quick Start Guide C3 and C4 in the event input can also be people counting interface. C3 controls people counting ● for entrance, while C4 controls people counting for exit. When the access control board detects signals in C3 and C4, the people number will be accumulated.
  • Page 55 Use the jumper cap to switch the serial port communication mode with the lane controller. By default, the interface is wired and it is in RS-485 communication mode. If wiring other controllers (compatible with Hikvision communication protocol), use the jumper cap to switch between RS-485 and RS-232 communication mode.
  • Page 56 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-11 Interface and Corresponded UART No.
  • Page 57: Rs-485 Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.5 RS-485 Wiring Note There are four RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR ● code scanner, fingerprint and card reader, card recycler, text screen, fingerprint reader, and face recognition terminal.
  • Page 58: Rs-232 Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.6 RS-232 Wiring Note There are three RS-232 interfaces (UART4, UART7, and UART8). UART7 and UART8 can connect QR code scanner, and card recycler, while UART4 can connect QR code scanner, card recycler, and face recognition terminal.
  • Page 59: Wiegand Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.7 Wiegand Wiring Note Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand card reader. 5.6.8 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can control the barrier status.
  • Page 60 DS-K3B801SX Series Swing Barrier Quick Start Guide to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit. Note Use the jumper cap to switch the relay status. For details, see Barrier Control Relay Output Mode . Entering Wiring Exiting Wiring...
  • Page 61: Alarm Output Wiring

    DS-K3B801SX Series Swing Barrier Quick Start Guide 5.6.9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) . 5.6.10 Exit Button Wiring You can view the exit button wiring diagram.
  • Page 62 DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 5-12 Exit Button Wiring...
  • Page 63: Chapter 6 Device Settings

    DS-K3B801SX Series Swing Barrier Quick Start Guide Chapter 6 Device Settings After installation and wiring completed, you should set the barriers closed position (study mode) before entering the working mode. You can also set the test mode, normal mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the access control board.
  • Page 64: Pair Keyfob (Optional)

    DS-K3B801SX Series Swing Barrier Quick Start Guide 4. Power off the device. 5. Set the No.1 switches of the 8-digit DIP Switch on the main control board by referring to the following figure. 6. Power on the device again. Note For details about the DIP switch value and meaning, see DIP Switch Description.
  • Page 65: Initialize Device

    DS-K3B801SX Series Swing Barrier Quick Start Guide Note Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the ● keyfob will select only one of them to pair. For details about DIP switch value and meaning, see DIP Switch . ●...
  • Page 66: Switch To Rs-485/Rs-232 Mode

    DS-K3B801SX Series Swing Barrier Quick Start Guide Note Make sure no persons are in the lane when powering on the device. 6.4 Switch to RS-485/RS-232 Mode Take the Serial Port 4 and on the access control board as an example. If the Jumper cap's position is like the picture displayed below.
  • Page 67: Switch Relay Output Mode (No/Nc)

    DS-K3B801SX Series Swing Barrier Quick Start Guide Figure 6-3 Jumper Cap Status of RS-232 Interface 6.5 Switch Relay Output Mode (NO/NC) 6.5.1 Barrier Control Relay Output Mode The pins of the barrier control relay on the access control board is as below: Figure 6-4 Pin Appearance The jumper cap's position of barrier opening for entrance (NO) is as below:...
  • Page 68: Alarm Relay Output Mode (No/Nc)

    DS-K3B801SX Series Swing Barrier Quick Start Guide The jumper cap's position of barrier opening for exit (NO) is as below: The jumper cap's position of barrier closing for entrance (NC) is as below: The jumper cap's position of barrier closing for exit (NC) is as below: 6.5.2 Alarm Relay Output Mode (NO/NC) Alarm Relay Output Mode (NO): Alarm Relay Output Mode (NC):...
  • Page 69: Chapter 7 Activation

    Get the SADP software from the supplied disk or the official website http:// ● www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 70: Activate Device Via Client Software

    DS-K3B801SX Series Swing Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 71 DS-K3B801SX Series Swing Barrier Quick Start Guide Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 72: Appendix A. Tips For Scanning Fingerprint

    DS-K3B801SX Series Swing Barrier Quick Start Guide Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
  • Page 73 DS-K3B801SX Series Swing Barrier Quick Start Guide Environment The scanner should avoid direct sun light, high temperature, humid conditions and rain. When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your finger and scan again. Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods.
  • Page 74: Appendix B. Dip Switch

    DS-K3B801SX Series Swing Barrier Quick Start Guide Appendix B. DIP Switch B.1 DIP Switch Description The DIP switch is on the main lane control board. No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
  • Page 75 DS-K3B801SX Series Swing Barrier Quick Start Guide Device Mode Function Decimal Value DIP Switch Address Diagram Memory Mode Enable Memory Mode Disable Memory Mode Keyfob Paring Disable Keyfob Mode Paring Mode Enable Keyfob Paring Mode 5 to 8 Passing Mode Controlled Bi- direction Controlled...
  • Page 76 DS-K3B801SX Series Swing Barrier Quick Start Guide Device Mode Function Decimal Value DIP Switch Address Diagram Prohibit Entrance and Controlled Exit Prohibit Entrance and Free Exit...
  • Page 77: Appendix C. Event And Alarm Type

    DS-K3B801SX Series Swing Barrier Quick Start Guide Appendix C. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible...
  • Page 78: Appendix D. Table Of Audio Index Related Content

    DS-K3B801SX Series Swing Barrier Quick Start Guide Appendix D. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions.
  • Page 79: Appendix E. Error Code Description

    DS-K3B801SX Series Swing Barrier Quick Start Guide Appendix E. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason Code Error Reason Code...
  • Page 80 DS-K3B801SX Series Swing Barrier Quick Start Guide Error Reason Code Error Reason Code Lower Second IR Beam Obstruction Triggered Lower Third IR Beam Triggered 19 Exceeding Studying Range Lower Fourth IR Beam Motor Exception Triggered...
  • Page 81: Appendix F. Communication Matrix And Device Command

    Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure F-2 Device Command...