7 Appendix
7.1 Regulatory Status
7.1.1 CE / UKCA Marking
We herewith declare that the bearingless fan BFS-i04, in its various configurations, is in conformity with the
below mentioned European Directives and UK Statutory Instruments.
Machinery Directive 2006/42/EU / SI 2008/1597:
The machinery directive essentially has been followed by a risk analysis, according to mitigation actions and
a user manual for safe operation. For the design and testing the following standards are used as a guideline:
ISO 12100
EMC Directive 2014/30/EU / SI 2016/1091:
The following standards of the EMC directive are tested and confirmed at a certified laboratory:
EN 61000-6-2
EN 61000-6-4
7.1.2 ATEX / UKEX / IECEx Certification and Marking
Specific BFS-i04 bearingless fans together with specific accessories are in conformity with the requirements
of the Directive 2014/34/EU, SI 2016 Nr. 1107 and the applicable IEC standards. The following standards are
tested and confirmed at a certified laboratory.
IEC / EN 60079-0:2018
IEC / EN 60079-18:2015
IEC / EN 80079-36:2016
IEC / EN 80079-37:2016
®
The Levitronix
Ex-conform bearingless fans are marked clearly and in accordance with the ATEX Directive,
UK SI and the relevant IECEx standards.
Classification:
Explosion Groups:
Thermal Classification:
UL Correspondence:
7.1.3 Disposal of Equipment – WEEE Directive 2012/19/EU
Follow local legislation for disposal of equipment. In the European Union (EU) marked ( ) devices are
governed by the European WEEE Directive 2012/19/EU. Do not dispose with normal waste.
PL-3507-00, Rev00, DCO# 23-128
Safety for machinery – principles for risk assessments: used for system risk analysis.
Generic standards, Immunity for industrial environments
Generic standards, Emission standard for industrial environments
Explosive atmospheres - General requirements
Explosive atmospheres - Equipment protection by encapsulation "m"
Explosive atmospheres - Non-electrical equipment for explosive atmospheres - Basic method and
requirements
Explosive atmospheres - Non-electrical equipment for explosive atmospheres - Non electrical type of
protection constructional safety "c", control of ignition source "b", liquid immersion "k"
II 2G Ex h mb IIC T6 Gb
1258
II 2D Ex h mb IIIC T85 °C Db
Category 2GD (Zone 1 for Gas and Zone 21 for Dust)
Group IIA: Propane (IPA), Methane, Acetone, Acetaldehyde
Group IIB: Ethylene, Ethylene-glycol
Group IIC: Acetylene, Hydrogen (not carbon disulfide)
Group IIIC: conductive dust
Thermal classification of motor is T6 85°C / 185°F for maximum full-load operating temperature at a
maximum gas temperature of 40°C / 104°F.
ATEX / IECEx listing corresponds to UL hazardous location Class 1 Division 2.