Datamax I-Class Mark II I-4212E/203 Operator's Manual page 60

Table of Contents

Advertisement

Diagnostics
The Diagnostics menu contains testing functions and printhead reporting selections:
Hex Dump Mode*
Options Testing*
Print Test Rate (min)*
Sensor Readings*
Ribbon Sensor Limits*
iPH Report*
Flash Module Report*
Items denoted with an asterisk (*) are only accessible through the Advanced Menu.
The menu selections are defined as follows:
DISPLAYED ITEM
HEX DUMP MODE
ENABLE
DISABLE
FILE CAPTURE
OPTIONS TESTING
TEST PRESENT
SENSOR
TEST CUTTER
PERFORM
TEST
001 TIMES
TEST GPIO
MONITOR
GPIO INPUT
TEST GPIO
OUTPUT
PRINT SIGNAL
INFO
PRINT TEST RATE
(MIN)
000
Chapter 4 – Menu System
Determines how the printer handles the data received from a host, where:
The printer outputs the raw ASCII data it receives without interpretation; no
processing occurs.
Processes data normally. (Default Setting)
Saves the incoming data to Module H (USB thumbdrive) if present; otherwise, the
file is stored on Module G. The file name, in the form [dmx_xxx_yyy.dpl], where
the count is automatically incremented for every capture and a unique printer time
stamp (xxx), is assigned.
Performs printer option diagnostics or monitors and outputs test results, where:
Performs a functional test of the Present Sensor by indicating LABEL PRESENTED
(when a label blocks the sensor) and LABEL NOT PRESENTED (when no label
blocks the sensor). (Note that this test can also be used to check the sensor
function of the Peel & Present option.)
Performs a functional test of the Cutter, where:
Cycles the cutter blade a selected number of times (0 - 999), with PASS / FAIL
results given for each cycling attempt.
Performs a functional test of the GPIO port, where:
Displays input signal logic values for Start of Print (SOP).
If unconnected, a zero or one may be displayed.
Displays output signal logic values for End of Print (EP) and Service Required (SR).
To change an output signal state, cursor over the displayed state
to select and then toggle it using the UP or Down Arrow Buttons.
Prints a reference label containing GPIO signal names, pin assignments,
programmed settings, and current signal states.
Sets a label-to-label delay interval (0 - 120 minutes) when Test label batch
printing, where:
Is the Default Setting.
ITEM DESCRIPTION