Advanced Entry Calibration (continued)
Step
Action
Use the UP and DOWN Arrow
buttons to set the Gain Number to
00.
F
Record the sensor reading as a
Label Value for Gain Number 00 in
a table (32 rows by four columns,
with headings similar to those
shown below.)
Gain Number
00
01
02
...
31
Step
Action
Use the UP and DOWN Arrow
buttons to increment the Gain
Number by one and then Record
G
the Label Value.
Repeat this process for each Gain
Number.
Gain Number
00
01
02
...
31
Chapter 3 - Printer Operation
Displayed Message
TRAN SENSOR GAIN
00
(0 - 31)
Sample Calibration Table
Label Value
TOF Value
252
Displayed Message
TRAN SENSOR GAIN
01
(0 - 31)
Sample Calibration Table
Label Value
TOF Value
252
250
248
...
09
Comment
This is the Label Value for a gain
setting of 00.
Difference Value
Comment
This is the Label Value for a gain
setting of 01.
Difference Value
26