Agilent Technologies 16048A Operation And Service Manual
Agilent Technologies 16048A Operation And Service Manual

Agilent Technologies 16048A Operation And Service Manual

Test leads

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Keysight / Agilent 16048A at our website:

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 16048A

  • Page 1 (217) 352-9330 | Click HERE Find the Keysight / Agilent 16048A at our website:...
  • Page 2 Agilent 16048E Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan, Ltd. Agilent PN 16048-90041 March 2000 Printed in: Japan Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 WARNINGS elsewhere in this manual may impair the protection provided by the equipment. In addition it violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the customer’s failure to comply with these requirements. • Ground The Instrument...
  • Page 4 Because of the danger of introducing additional hazards, do not install substitute parts or perform unauthorized modifications to the instrument. Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained.
  • Page 5 Instruments are warranted for a period of one year. Fixtures and adapters are warranted for a period of 90 days. During the warranty period, Agilent Technologies Company will, at its option, either repair or replace products that prove to be defective.
  • Page 6 Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products. For any assistance, contact your nearest Agilent Technologies Sales and Service Office. Addresses are provided at the back of this manual. Safety Symbol General definitions of safety symbols used on the instrument or in manuals are listed below.
  • Page 7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Table Of Contents

    Contents 1. Operation Product Description ..........10 Specifications .
  • Page 9 Contents Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10: Operation

    Operation This operating note provides complete information on the 16048E Test Leads. The 16048E is shown in Figure 1-1, its physical dimensions are given in Table 1-1. To order additional copies of this operating note, use the part number listed on the rear cover.
  • Page 11: Product Description

    Operation Product Description Product Description The 16048E consists of a direct attachment, 4-terminal pair type fixture which is equipped with four BNC (m) terminated-coaxial test leads. These test leads are used to attach user-fabricated test fixtures. Cable length is 4 meter. The 16048E is shown in Figure 1-1.
  • Page 12: Specifications

    Operation Specifications Specifications Table 1-1 Specifications of the 16048E Function: 4-terminal pair type fixture which is equipped with four BNC (m) terminated-coaxial test leads. Connector Type: BNC male Cable Length: Approximately 4 m Test Leads Length: Approximately 3.8 m Maximum Voltage: ±...
  • Page 13: Compensation For Fixture Residual Impedance Error

    Operation Compensation for Fixture Residual Impedance Error Compensation for Fixture Residual Impedance Error The 16048E has inherent stray capacitance, residual inductance, and residual resistance that affect the accuracy of measured values. To compensate for, or negate, these residuals to minimize measurement error, the instrument’s Open/Short compensation procedure should be performed.
  • Page 14: Operation

    Operation Operation Operation Setup and Measurement Procedure Setup and measurement procedure is as follows: 1. Connect the 16048E directly to the UNKNOWN terminals and GUARD terminal of the instrument. 2. Connect the user-fabricated test fixture to the test leads. 3. Perform Open/Short compensation as described in the instrument’s operation manual.
  • Page 15 Operation Operation Chapter 1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Service

    Service Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 17: Maintenance

    Take special care when cleaning contacts. To order parts, use the Agilent Technologies part numbers listed in Table 2-1 and Table 2-2. If a faulty part is located in an assembly...
  • Page 18 Service Maintenance Table 2-1 Parts Identification 1/2 Reference Agilent Part No. Qty. Description 16048-04013 COVER TOP 2360-0192 SCREW 16048-04014 COVER BOTTOM 1250-0089 CONTACT 1250-0052 CONNECTOR BNC 16047-40000 STOPPER 2190-0260 WASHER 2200-0013 SCREW 16048-61612 CABLE ASSEMBLY 0400-0203 GROMET 16048-04015 COVER TOP 2360-0192 SCREW TEST LEAD (1 through 7)
  • Page 19 Service Maintenance Reference Agilent Part No. Qty. Description 1250-0188 CONNECTOR BNC 2190-0016 WASHER 2950-0001 16032-60001 BNC BRACKET (9 through 12) Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20 REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative.

Table of Contents