Download Print this page
Agilent Technologies 16047A Operation And Service Manual

Agilent Technologies 16047A Operation And Service Manual

Text fixture

Advertisement

Quick Links

Agilent Technologies 16047A Operation And Service Manual

Advertisement

loading

Summary of Contents for Agilent Technologies 16047A

  • Page 1 sales@artisantg.com artisantg.com (217) 352-9330 | Click HERE Find the Keysight / Agilent 16047C at our website:...
  • Page 2 November 2008 Change 1 Add the note, under Figure 1-3 on page 13. NOTE This short bar is not included in 16047A. It is prepared as option of 16047A. Option number is 16047A-701. Copyright 2008 Agilent Technologies ○ Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 SOCKET ASSEMBLY (31,32 and 33) 5000-4226 Short Bar 1 This short bar is not included in 16047A. It is prepared as option of 16047A. Option number is 16047A-701. Copyright 2008 Agilent Technologies ○ Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4 Agilent 16047A Test Fixture Operation and Service Manual Third Edition Agilent PN 16047-90011 December 1999 Printed in: Japan Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 5 In addition it violates safety standards of design, manufacture, and intended use of the instrument. The Agilent Technologies assumes no liability for the customer’s failure to comply with these requirements. 16047A comply with INSTALLATION CATEGORY I and POLLUTION NOTE DEGREE 2 in IEC61010-1.
  • Page 6 Because of the danger of introducing additional hazards, do not install substitute parts or perform unauthorized modifications to the instrument. Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained.
  • Page 7 Instruments are warranted for a period of one year. During the warranty period, Agilent Technologies will, at its option, either repair or replace products that prove to be defective.
  • Page 8 Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products. For any assistance, contact your nearest Agilent Technologies Sales and Service Office. Addresses are provided at the back of this manual. Safety Symbol General definitions of safety symbols used on the instrument or in manuals are listed below.
  • Page 9 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10: Table Of Contents

    Contents 1. Operation Introduction 10 Product Description 10 Specifications 11 Typical Characteristics 12 Compensation for Fixture Residual Impedance Error 13 2. Service Maintenance 16 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11 Contents Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12 Operation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13: Operation Introduction

    Introduction This chapter provides complete information of the 16047A Test Fixture. Product Description The 16047A Test Fixture is designed for use with 4 terminal-pair LCR Meters and Impedance Analyzers. It is a direct attachment,4-terminal pair configuration type test fixture for measurements on both axial and radial lead components.
  • Page 14: Specifications

    Operation Introduction Specifications Table 1-2 Specification of the 16047A Function: For use with 4 terminal-pair LCR Meters and Impedance Analyzers. Measurable Axial and radial lead components. components: Contact inserts: Three kinds: one for axial lead components, one for radial lead components, and one for radial short lead components.
  • Page 15: Typical Characteristics

    Operation Introduction Typical Characteristics Table 1-3 Typical characteristics ≥ Incremental Error at f 1 MHz Parameter reading error Offset Value for D Á   ± × ----- -   f is the measurement frequency in MHz. The incremental errors calculated from NOTE the equation in the table for measurements at frequencies above l MHz are additive.
  • Page 16: Compensation For Fixture Residual Impedance Error

    Operation Introduction Compensation for Fixture Residual Impedance Error The 16047A has inherent stray capacitance, residual inductance, and residual resistance that affect the accuracy of measured values. To compensate for, or negate, these residuals to minimize measurement error, the instrument’s Open/Short compensation procedure should be performed. The procedure is given in the instrument’s operating manual.
  • Page 17 Operation Introduction Chapter 1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18: Service

    Service Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19: Maintenance

    Maintenance Maintenance The internal wiring of the 16047A is shown in Figure 2-1 and an exploded View (for parts identification) in Table 2-2. Do not disassemble any further than shown. Maintenance consists principally of cleaning contacts and replacing worn or damaged parts.
  • Page 20 Service Maintenance Figure 2-2 Parts Identification Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21 Service Maintenance Table 2-1 Replaceable Parts List. Reference Agilent Part No. Description 16047-04013 COVER-BOTTOM 2950-0043 2190-0016 WASHER 0515-1467 SCREW 16061-50022 BASE 1250-1798 CONNECTOR-BNC 16012-7122 CONNECTOR-BNC 16047-40000 STOPPER 2190-0206 WASHER 0515-1550 SCREW 0515-0914 SCREW 16047-04011 COVER-TOP 0515-0914 SCREW 16047-00618 SHIELD PLATE 16061-50024 SOCKET 0515-1467...
  • Page 22 Service Maintenance Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23 Service Maintenance Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24 REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative.