Kohler 1835-GW-0 Installation And Care Manual page 21

Bath with airjets with heated surface
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (cont.)
Bath System
Symptoms
6.
Blower motor starts, some
but not all airjets are
bubbling.
7.
Blower motor runs but no
air bubbles are formed.
8.
Blower motor operates,
air bubbles are formed,
zone controls work, but
variable speed feature
does not work.
Blower motor won't turn
9.
off when the Power icon
on user keypad is
pressed.
10. A zone does not produce
air bubbles but another
zone operates normally.
11. Surge mode does not
work.
Kohler Co.
Probable Causes
A. Blower motor speed is too low.
B. Blower air inlet is blocked.
C. Blower motor does not work.
D. Blower motor discharge is
blocked.
E. Check valve does not work.
F.
Airjets are clogged.
G. Some zones are closed.
A. Blower air inlet is blocked.
B. Airjets are clogged.
C. Check valve does not work.
D. Blower motor does not work.
E. Control does not work.
A. Blower air inlet is blocked.
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work.
D. Blower motor does not work.
E. Control does not work.
A. User keypad does not work.
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work.
A. Zone is not selected.
B. Butterfly valve does not work.
C. Loose, disconnected, or
damaged wiring harness.
D. User keypad does not work.
E. Control does not work.
A. User keypad does not work.
B. Control does not work.
21
Recommended Action
A. Increase speed set point to blower
motor.
B. Clear blower air inlet.
C. Replace the blower motor.
D. Clear blockage.
E. Replace the check valve.
F.
Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
G. Operate all zones.
A. Clean blower air inlet.
B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
C. Replace the check valve.
D. Replace the blower motor.
E. Replace the control.
A. Clear blower air inlet.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the user keypad.
D. Replace the blower motor.
E. Replace the control.
A. Replace the user keypad.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the control.
A. Select the zone according to the
instructions in the "Operating
Instructions" section.
B. Replace the butterfly valve.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary.
D. Replace the user keypad.
E. Replace the control.
A. Replace the user keypad.
B. Replace the control.
1204120-2-A