4.6.4 Fusing
The temperature change of the heat roller's surface is changed to the resistance value through the thermis-
tor. By converting the voltage value, which impressed to the resistance, to the digital value through the AD
converter, the temperature is decided. The AC power is controlled by comparing the target temperature to
the value from the thermistor. If the value from the thermistor is out of the controlling range while control-
ling the fusing, the error stated in the table occurs. (For the domestic model, the Q-PID method has been
applied.)
4.6.4.1 Heat Lamp Method
Error
Open heat error
When warming up, it has been lower
than 68°C over 28 seconds
Lower heat error
• Standby:
It has been lower than 80°C over 10 seconds
• Printing:
- 2 consecutive pages: it has been lower than
- 3 consecutive page; it has been 25°C lower
Over heat error
It have been higher than 220°C over 3 seconds
4.6.4.2 Q-PID Method
Error
Open heat error
When preheating, it has been lower than 68°C
over 15 seconds.
Lower heat error
• After finishing the preheating stage,
it has not reached 100°C (preheating stop
temperature) during 15 seconds since the
temperature is over 68°C.
• Printing
1) When the main motor is on and after 0.92
2) From the 2 consecutive pages, it has been
Over heat error
• the error is not displayed immediately when
it has been over 220°C over 3 seconds.
The temperature after the 3 seconds is checked.
If it is over 240°C, it is error.
• If the temperature has been higher than 220°C
over 25 seconds, it is an error even through the
temperature doesn't reach 240°C.
Samsung Electronics
Description
145°C over 4 seconds.
than the fixed fusing temperature over 4 seconds.
Description
second, it has not reached the 160°C
during 20 seconds.
20°C lower than the fusing temperature
over 4 seconds.
S U M M A RY OF PRO D U C T
DCU
LED Displat
60
All LED are flashing.
62
All LED are flashing
68
All LED are flashing
DCU
LED Displat
60
All LED are flashing
62
All LED are flashing
68
All LED are flashing