INSTALLATION
(continued)
Cabinet construction for built in oven
For the best integration within a kitchen, install this
appliance in a cupboard that gives a flush fit with the
surrounding cupboard fronts. A recess of 20mm is ideal.
NOTE: Your appliance must be mounted on a horizontal
surface for the full width and depth of the product.
NOTE: A ventilation slot 20mm wide is required at the
rear of the base of the cabinet floor.
900mm
cupboard
door
876mm
Mounting holes
NOTE: If a powerpoint is fitted it must be accessible with
the appliance installed.
8
INSTALLATION OF THE APPLIANCE
20mm
20mm
(see NOTE)
100mm
max.
Infill panel max.
16mm thickness
900mm
*20mm
see note
below
20mm
slot
580mm
*Refer to cooktop installation instructions for
required clearance between cooktop and oven.

WIRING REQUIREMENTS

The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS 3000 Wiring Rules.
Local regulations, municipal building codes and
other statutory regulations.
For New Zealand Only:
The cooking range must be connected to
the supply by a supply cord fitted with the
appropriately rated plug that is compatible with
the socket-outlet fitted to the final sub-circuit in
the fixed wiring that is intended to supply this
cooking range.
Supply cord size required:
WVE9515SD - 2.5mm
2
The Data plate gives information about rating and is
located behind the bottom of the oven door.
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000).
Wiring MUST be protected against mechanical
failure (AS/NZS 3000).
Disconnection in the fixed wiring must occur in
accordance with the AS/NZS 3000 wiring rules.
The cooker MUST be properly earthed.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance
test after manufacture. If the resistance reading is
low at installation, it is probably caused by moisture
from the atmosphere being absorbed by the
elements after the range has been produced. (pass
at 0.01 M AS/NZS 3000 Wiring Rules).
Note: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
Connecting to services and commissioning
This appliance must be installed by an authorised
person, according to all codes and regulations of:
ELECTRICAL supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS 5601.1.
AS/NZS 3000.
Plastic clips
Plastic clip
Securing points
Hard wiring detail
1.
Remove terminal cover plate from rear panel
of appliance.
2.
Fit wires through hole in back panel below
terminal cover.
3.
Engage wires into plastic clip. Secure plastic
clip with two long silver screws (supplied in
separate bag).
4.
Replace cover plate onto rear panel.
Electrical connection location - built-in models
113
99
Entry point of electrical cable
MODEL
TOTAL KW
WVE9515SD
3.6
WIRING REQUIREMENTS
9