Page 3
Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
PRODUCT SAFETY SAFETY SYMBOLS The following safety symbols may be used on the product and throughout the product documentation. MEANING / DESCRIPTION SYMBOL PROTECTIVE EARTH (GROUND) To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protective earth (ground) electrode.
I/O signals that may be present. Blanking panels are available to order from Pickering. If the product is not used in this manner for example by using an extender card then additional care must be taken to avoid contact with exposed signals.
Page 8
CAUTION - PRODUCT DOCUMENTATION SYMBOL Suitably qualified & trained users should ensure that the accompanying documentation is fully read and understood before attempting to install or operate the product. SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS All cleaning and servicing requires the equipment to be isolated and disconnected from the power source and user I/O signals (refer to the Maintenance Section).
• 3 Year Warranty The 60-555 is a high density double pole 512x8 matrix suitable depth. It is programmable via the LAN interface using Pickering’s for signal routing in large ATE systems. It is easily expanded to generic switch driver. Standard (W3C) web browsers can be used produce larger sizes, for example, two units can be linked to create to change the configuration and access the soft front panels.
Page 10
Overview SECTION 1 - TECHNICAL SPECIFICATION pickering High Density 512x8 2-Pole Matrix – 60-555/556 Matrix Expansion The 60-555/556 may be expanded to larger matrix sizes by using cabling to daisy-chain the Y signals. The illustrations below show four 60-555-008 512x8 2-pole matrices interconnected as a 2048x8 2-pole matrix using specially constructed cables.
Page 11
Specifications SECTION 1 - TECHNICAL SPECIFICATION pickering High Density 512x8 2-Pole Matrix – 60-555/556 Relay Type LAN Interface Compliant to LXI Standard 1.4, the 60-555/556 has a 1000Base-T The 60-555/556 is fitted with high quality electro-mechanical Ethernet Interface via a standard RJ-45 connector mounted on the relays.
Page 12
60-556-004 Product Customization LXI High Density 320x4 2-Pole EMR Matrix 60-556-005 Pickering LXI units are designed and manufactured on our own LXI High Density 384x4 2-Pole EMR Matrix 60-556-006 flexible manufacturing lines, giving complete product control and LXI High Density 448x4 2-Pole EMR Matrix 60-556-007 enabling simple customization to meet very specific requirements.
Page 13
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
Page 14
Signal Routing Software Our signal routing software, Switch Path Manager, automatically selects and energizes switch paths through Pickering switching systems. Signal routing is performed by simply defining test system endpoints to be connected together, greatly accelerating Test System software development.
Page 15
LAN interface from a remote computer using the unit’s unique Ethernet address. Programming documentation for the unit as well as data for Pickering’s other LXI compatible switching products is stored in the embedded processor and can be downloaded over the LAN interface. Status LEDs on the front of the chassis indicate the condition of the unit and the LAN connection.
Page 16
SECTION 2 - TECHNICAL DESCRIPTION pickering MATRIX ARCHITECTURE The following diagrams show the architecture of the 60-555 and 60-556 matrices in more detail than the basic diagram on Page 1-1. The 60-555 consists of up to eight 64x8 2-pole sub-matrices linked by two analog buses - see Figure 2-2.
Page 17
SECTION 2 - TECHNICAL DESCRIPTION pickering 2-Pole Isolation Switches All Matrix Crosspoints Are 2-Pole 64 x 4 2-POLE MARIX CARD 1 X128 2-Pole Isolation Switches 64 x 4 2-POLE MARIX CARD 2 X129 X192 2-Pole Isolation Switches 64 x 4 2-POLE MARIX CARD 3...
Page 18
SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page 2.4...
The product is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident. 2. Ensure that the designated area for the product is of a flat and solid construction to support its weight.
Page 20
SECTION 3 - INSTALLATION pickering Figure 3-2. Front view of the High Density 2-Pole EMR Matrix showing the intake slots for cooling air SETTING THE IP ADDRESS To use the 60-555/556 High Density Matrix over a LAN connection it should be set up and configured as described in the “LXI Getting Started Guide”...
SECTION 3 - INSTALLATION pickering Figure 3-4. Example configuration window used to manually set the IP address of a Pickering LXI device INSTALLING THE SOFTWARE From the device web page, select ‘Driver Download’ from the menu at the left of the page. This will retrieve the driver from the instrument and install it on your PC.
Page 22
SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page 3.4...
SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES LXI UNITS For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
SECTION 4 - PROGRAMMING GUIDE pickering PROGRAMMING THE 60-555/556 The 60-555 is a matrix which has a maximum size of 512 connections on its X axis and 8 on its Y axis. Smaller versions are also available. The x dimension is built using a set of 64 wide sub-matrix sections, each connected to one of two y-buses using a set of isolation relays, 16 per sub-matrix.
SECTION 4 - PROGRAMMING GUIDE pickering Sub-Unit Allocations The High Density Matrix is programmed using three sub-units; One for the entire matrix, one for all the Analog Bus A isolation switches, and one for all the Analog Bus B isolation switches. The following tables show the sub- unit allocations for each version of the 60-555 and 60-556 High Density Matrix.
Page 26
SECTION 4 - PROGRAMMING GUIDE pickering Sub-Unit 2 - ya Sub-Unit 1 2-Pole Isolation Switches 512x8 2-Pole Matrix (X1-Y1 to X512-Y8) All Matrix Crosspoints Are 2-Pole Sub-Unit 3 - yb 2-Pole Isolation Switches 64 x 8 2-POLE MARIX CARD 1...
Page 27
SECTION 4 - PROGRAMMING GUIDE pickering Sub-Unit 2 - ya Sub-Unit 1 2-Pole Isolation Switches 512x4 2-Pole Matrix (X1-Y1 to X512-Y4) All Matrix Crosspoints Are 2-Pole Sub-Unit 3 - yb 2-Pole Isolation Switches 64 x 4 2-POLE MARIX CARD 1...
The Direct I/O driver is in reality composed of a suite of separate libraries which interact to provide full control of a Pickering LXI device. In the case of a switch card the communications library picmlx, and the switching library piplx, are needed.
The following code snippet demonstrates the minimum steps required to operate a switch on a Pickering LXI unit. Firstly a device session is opened on the card located at bus 0, device 5 inside the LXI unit located at 192.168.1.100.
Page 30
SSH (Secure SHell) Interface Refer to the section “Command Line Control of Pickering LXI Instruments” on the following pages for details of how to open this interface and general information on the command set available. After opening an SSH session the 60-555/556 is controlled as follows:...
LXI instrument from the Windows utility PILMon and provides identical functionality. Enabling the Command Line Control Utility Pickering LXI devices do not provide an SSH server in the normal configuration state, the service must be explicitly enabled.
Page 32
SECTION 4 - PROGRAMMING GUIDE pickering Step 2 - Enable the SSH server Select the Diagnostics page from the main menu LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page 4.10...
Page 33
SECTION 4 - PROGRAMMING GUIDE pickering Click on Start SSH server The SSH server is now operative and instrument control access is available from an external SSH client application. NOTES: The password and state of the SSH server are stored in non-volatile memory within the LXI device and so will remain in effect even after a power cycle.
Page 34
SECTION 4 - PROGRAMMING GUIDE pickering Instrument Control from an SSH Client In the following examples the SSH client PuTTY is used, the user will have to adapt the instructions for any other client. First start up the SSH client and enter the IP address of the LXI device. The user will be prompted for a login name and password.
Page 35
Before attempting to control a card it is important to understand the switch architecture of that card and to know how to address the required switch. Each Pickering switch card is represented as a set of one or more sub-units, each sub-unit containing one or more switches.
Page 36
SECTION 4 - PROGRAMMING GUIDE pickering Commonly used mnemonic commands Will list all the open cards, providing the Card Number of each which is essential for further control of a card, also provided are the details of the card model number and architecture.
Page 37
= UNMASK|MASK an individual output MB <bit_pattern> = set OUTPUT sub-unit mask (to hex bit-pattern) = view sub-unit output mask (as hex bit-pattern) = take control of all Pickering switch cards = release control of all Pickering switch cards VO <bus> <slot> = open card at specified location VC <card>...
SECTION 5 - CONNECTOR INFORMATION pickering SECTION 5 - CONNECTIONS X449 to X512 X193 to X256 X129 to X192 X385 to X448 & Y1B to Y8B X321 to X384 X65 to X128 X1 to 64 X257 to X320 & Y1A to Y8A Figure 5-1.
Page 40
SECTION 5 - CONNECTOR INFORMATION pickering Ethernet Port LAN Reset Service Port (for Pickering diagnostics only) IP Address Display Mains Inlet Fuses Power Switch Figure 5-2. Rear Panel Connector Layout for the 60-555/556 LXI High Density 2-Pole EMR Matrix LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556...
Page 41
SECTION 5 - CONNECTOR INFORMATION pickering The following diagrams show the connector pin-out information for a fully populated 60-555 High Density 2-Pole Matrix with a size of 512x8. The variants with smaller matrix sizes have pin numbering in the same sequence as shown in the following diagrams up to the maximum X or Y count specified.
Refer to the Warnings and Cautions at the front of this manual INSTALLATION PROBLEMS The Plug & Play functionality of Pickering switching products generally ensures trouble-free installation. If you do experience any installation problems you should first ensure that all cables are properly connected.
Q All of my device’s lights are on, why don’t I see a green Ready light, even after a few minutes? Your device has a fault, contact your local sales office. Please contact your local Pickering Interfaces sales office for any further support or email: Lxisupport@pickeringtest.com You can also visit our website for product updates, help and downloadable materials at: http://www.pickeringtest.com...
USING BIRST ™ (BUILT-IN RELAY SELF TEST) The Pickering Interfaces BIRST (Built-In Relay Self Test) Tool provides a simple means of testing selected Pickering Interfaces switching products, including this model. The tool can be used to find relay faults or to provide confirmation that a product is operating correctly, either as part of the regular system calibration or because a system fault is suspected and the switch system needs to be eliminated from the fault finding procedure.
Page 54
SECTION 7 - MAINTENANCE INFORMATION pickering Figure 7-1. PCB layout for one 64x8 Matrix Board with relay positions highlighted LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page 7.8...
Page 55
SECTION 7 - MAINTENANCE INFORMATION pickering 60-555/556 CHASSIS PARTS LIST The 60-555 LXI High Density 2-Pole Matrix chassis contains two main Base boards and, depending upon the specific variant, up to two further Base boards and four Matrix Daughter boards. As well as the matrix boards, the chassis houses a Power Supply, Power Distribution Board, Bridge Board and a Microcontroller assembly.
Page 56
SECTION 7 - MAINTENANCE INFORMATION pickering Table 7-2. 60-555/556 LXI High Density Matrix Chassis Parts List for a fully loaded matrix (items highlighted in yellow are fitted to the 60-555 only and items highlighted in blue are fitted to 60-556 only)
Page 57
SECTION 7 - MAINTENANCE INFORMATION pickering LXI STATUS LED BOARD BIRST DAUGHTER BOARD FPGA BRIDGE MATRIX DAUGHTER BOARD - 64x8 2-POLE DAUGHTER BOARD MICROCONTROLLER MATRIX BASE BOARD “B” MIDDLE LEFT - 64x8 2-POLE MATRIX DAUGHTER BOARD - 64x8 2-POLE MATRIX BASE BOARD “A” LOWER LEFT - 64x8 2-POLE...
Page 58
SECTION 7 - MAINTENANCE INFORMATION pickering MATRIX DAUGHTER BOARD (PCB 2) MATRIX BASE BOARD “A” (PCB 1) LEFT RIGHT 192x8 2-POLE MATRIX (60-555-023 MATRIX DAUGHTER BOARD (PCB 2) & 60-556-023) MATRIX BASE BOARD “A” (PCB 1) MATRIX BASE BOARD “A” (PCB 3)
Figure 7-5 provides a diagram of how the boards are interconnected for a fully populated 512x8 2-pole matrix, and gives Pickering part numbers for the various assemblies. The different variants of the 60-555 are essentially the same but with different numbers of matrix boards fitted into the chassis. The 60-556 has the same construction as the 60-555 but is fitted with a different build of matrix board, giving a maximum overall size of 512x4.
Page 60
SECTION 7 - MAINTENANCE INFORMATION pickering The Matrix Base Boards “A” receive serial data for the relay drivers via ribbon cables from the FPGA Bridge Daughter Board, and power for the Base Board is fed from the PSU via the Distribution Board. The Left and Right Base Boards connect directly together allowing Y signals to be fed between the different sections of the matrix.
Page 61
SECTION 7 - MAINTENANCE INFORMATION pickering External LAN Connection Microcontroller Board (A-PC-1004) Ribbon Cable (C-CN-951) LXI Status LED Board (A-PC-481 Board B) Ribbon Cable (C-CN-991) BIRST Daughter 64x8 2-Pole Matrix Base Board “A” - Left (A-PC-1193-L) Board (A-PC-615) Ribbon Cable...
Page 62
SECTION 7 - MAINTENANCE INFORMATION pickering THIS PAGE INTENTIONALLY BLANK LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page 7.16...
APPENDIX A - FITTING RACK MOUNTING FLANGES Pickering’s LXI devices are supplied with mounting flanges to enable fitting into a standard 19 inch rack. The following procedure describes the attachment of the flanges to the unit’s side extrusions, a No.1 cross head screwdriver will be required.
Page 64
APPENDIX A - FITTING RACK MOUNTING FLANGES pickering THIS PAGE INTENTIONALLY BLANK LXI HIGH DENSITY 2-POLE EMR MATRIX 60-555/556 Page A.2...