Before moving the tumble dryer
again
A small quantity of condensed water
that remains in the area around the
pump after the drying process can run
out if the dryer is tilted. Recommenda-
tion: Start the Time Dry program for ap-
prox. 1 minute before transporting the
dryer. Any remaining condensed water
will then be fed into the condensed wa-
ter container (which you will need to
empty again) or out through the drain
hose.
Additional installation require-
ments
All installations must be carried
out in accordance with local regula-
tions.
Slot-in
This tumble dryer is suitable for pushing
under a countertop.
It is very important to avoid a
build-up of heat. The warm air which
is expelled from the dryer must be
able to dissipate. Warm air which
cannot dissipate could cause a fault.
- The appliance lid must not be re-
moved.
- The electrical socket must be located
in an accessible position near the
tumble dryer.
- Drying durations may increase
slightly.
Installing the dryer in a closet
Minimum installation distance
You must insert sufficiently large
ventilation openings into the closet
door. You can also open the closet
door slightly while the dryer is oper-
ating.
Otherwise, the dryer can overheat,
which can cause a fault.
Ensure that the dryer door can
be opened at any time.
Ensure that the laundry can easily be
removed at any time.