DANGER
Jump-starting a weak battery that is
cracked or frozen or has a low electrolyte
level or an open/shorted battery cell can
cause an explosion, resulting in serious
personal injury.
Do not jump-start a weak battery if these
conditions exist.
2.
Make sure that the booster battery is a good
and fully charged lead-acid battery at 12.6 V or
greater.
Note:
Use properly sized jumper cables with
short lengths to reduce voltage drop between
systems. Make sure that the cables are color
coded or labeled for the correct polarity.
CAUTION
Connecting the jumper cables incorrectly
(wrong polarity) can immediately damage
the EFI system.
Be certain of battery-terminal polarity
and jumper-cable polarity when hooking
up the batteries.
WARNING
Batteries contain acid and produce
explosive gases.
• Shield your eyes and face from the
batteries at all times.
• Do not lean over the batteries.
Note:
Ensure that the vent caps are tight and
level. Place a damp cloth, if available, over any
vent caps on both batteries. Also ensure that the
machines do not touch and that both electrical
systems are off and at the same rated system
voltage. These instructions are for negative
ground systems only.
3.
Connect the positive (+) cable to the positive (+)
terminal of the discharged battery that is wired
to the starter or solenoid as shown in
1. Positive (+) cable on
discharged battery
2. Positive (+) cable on
booster battery
3. Negative (–) cable on the
booster battery
4. Negative (–) cable on the
engine block
4.
Connect the other end of the positive cable to
the positive terminal of the booster battery.
5.
Connect the black negative (–) cable to the other
terminal (negative) of the booster battery.
6.
Make the final connection on the engine block of
the stalled machine (not to the negative battery
post), away from the battery, and stand back
(Figure
Figure
59.
1. Engine block
7.
Start the machine and remove the cables in
the reverse order of connection (disconnect the
negative cable from the engine block first).
48
Figure 59
5. Booster battery
6. Discharged battery
7. Engine block
60).
Figure 60
2. Negative (–) cable
g012785
g008804