Optional Internal Usb Card; Removing The Internal Usb Key - Dell EMC PowerEdge R750xs 60KKP Installation And Service Manual

Table of Contents

Advertisement

3. Confirm that the battery is operating properly, by performing the following steps:
a. Enter the System Setup, while booting, by pressing F2.
b. Enter the correct time and date in the System Setup Time and Date fields.
c. Exit the System Setup.
d. To test the newly installed battery, remove the system from the enclosure for at least an hour.
e. Reinstall the system into the enclosure after an hour.
f. Enter the System Setup and if the time and date are still incorrect, see

Optional internal USB card

NOTE:
To locate the internal USB port on the system board, see the

Removing the internal USB key

Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of
the USB memory key are 15.9 mm width x 57.15 mm length x 7.9 mm height.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
Steps
1. Holding the blue tag, lift the internal USB card to disconnect from the connector on the system board.
2. Remove the USB memory key from the internal USB card.
Figure 118. Removing the internal USB card
Next steps
Replace the internal USB
122