Fitting The Stability Bracket - Electrolux ZANUSSI ZCG7902 User Manual

Table of Contents

Advertisement

Carry out a gas tightness test after
connecting to the gas supply.
bayonet connector must be fitted in the
shaded area indicated in Fig.2. Take into
account that it must be possible to pull the
appliance forward sufficiently. Ensure the
hose does not become trapped when
pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED
MUST COMPLY WITH BS.669 CURRENT
EDITION.
LPG Flexible connections must be a type
suitable for L.P.G and capable of operation
up to 50 mbar and carry a red stripe, band or
label.

Fitting the stability bracket

It is recommended that if the appliance is to
be installed with a flexible supply pipe, a
stability bracket be fitted and is available
from your supplier (see Important Safety
Requirements). These instructions should
be read in conjunction with any leaflet
packed with the stability bracket.
1. Place the appliance in its intended
position and level appliance.
2. Mark off 300mm from the left hand side
of the appliance as shown in dimension
' A' , Fig 3a. This is the centre line of the
fixing bracket.
3. Draw a line 100mm from the front edge
of the feet (see Fig.3a) and remove
appliance from its position. Mark off
dimension ' B' (see Fig.3a) back from this
line on the centre line of the bracket to
locate the front edge of the lower
bracket.
Fix lower bracket (with two
fixing holes) to the floor then measure
the height from floor level to engagement
edge on back of appliance, dimension ' C'
of Fig. 3b.
The gas
50 100
Fig.2.
20mm
100mm
300mm
(A)
Fig.3a.
400
(C)
Fig.3b.
41