Weld Output Receptacles And Selecting Cable Sizes - Miller FieldPro Remote CE Owner's Manual

Table of Contents

Advertisement

5-6. Weld Output Receptacles And Selecting Cable Sizes*

NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Output
Terminals
!
Turn off power before
connecting to weld out-
put terminals.
!
Do not use worn, dam-
aged, undersized, or
repaired cables.
Electrode
Work
Output Receptacles
Ref. 255 179-B
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use.
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart)
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m)
or Less
Welding
Amperes
100
2/0 (70)
150
2/0 (70)
200
2/0 (70)
250
2/0 (70)
300
2/0 (70)
350
2/0 (70)
400
2/0 (70)
500
3/0 (95)
600
4/0 (120)
Not Exceeding***
150 ft
200 ft
250 ft
(45 m)
(60 m)
(70 m)
10 − 100% Duty Cycle
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
2 ea. 3/0
4/0 (120)
(2x70)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 4/0
(2x70)
(2x95)
(2x120)
300 ft
350 ft
400 ft
(90 m)
(105 m)
(120 m)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
3/0 (95)
4/0 (120)
4/0 (120)
2 ea. 2/0
2 ea. 2/0
4/0 (120)
(2x70)
(2x70)
2 ea. 2/0
2 ea. 3/0
2 ea. 3/0
(2x70)
(2x95)
(2x95)
2 ea. 3/0
2 ea. 3/0
2 ea. 4/0
(2x95)
(2x95)
(2x120)
2 ea. 3/0
2 ea. 4/0
2 ea. 4/0
(2x95)
(2x120)
(2x120)
2 ea. 4/0
3 ea. 3/0
3 ea. 3/0
(2x120)
(3x95)
(3x95)
3 ea. 3/0
3 ea. 4/0
3 ea. 4/0
(3x95)
(3x120)
(3x120)
Ref. S-0007-K 2013−10
OM-263 657 Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pipeworx 350 fieldpro907633