4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the rear. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Unit Specifications

.
Do not use information in unit specifications table to determine electrical service requireements. See Sections 5-4 and 5-5 for information on con-
necting input power.
Input
Power
Rated Output
350 A at 34
VDC, 60%
3-Phase
Duty Cycle*
*See Section 4-3 for Duty Cycle Rating.

4-3. Duty Cycle And Overheating

Overheating
SECTION 4 − SPECIFICATIONS
Voltage
Range in CV Mode
10−44 V
60% Duty Cycle
6 Minutes Welding
0
Minutes
Amperage
Range in
CC Mode
10−350 A
4 Minutes Resting
15
OR
Reduce Duty Cycle
RMS Amps
Input at Rated
Load Output,
50/60 Hz
3-Phase at
NEMA Load
Max.
Voltages and
Open-
Class I Rating
Circuit
380 V
400 V
Voltage
KVA
78 VDC
27.1
25.9
17.8
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen
minutes for unit to cool. Reduce
amperage or voltage, or duty cycle
before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
A or V
Ref. 216 568-A
OM-263 657 Page 11
KW
15.9