Download Print this page
DOLD INFOMASTER SMS RP 5812 Monitoring Technique

DOLD INFOMASTER SMS RP 5812 Monitoring Technique

Sms-telecontrol module

Advertisement

Quick Links

Monitoring Technique
INFOMASTER SMS
SMS-Telecontrol Module
RP 5812
Circuit Diagrams
I0
I1
I2
GND
I3
I0
I1
I2
I3
03
13
GND
04
14
03
04
13 14 23 24 33 34
RP 5812S, RP 5812PS, RP 5812PC
I0
I1
GND
AI0
AI0
AGND
I0
I1
(+)
0...10V
GND
03
13
04
14
03
04
13 14
AO0
RP 5812S/001, RP 5812PS/001, RP 5812PC/001
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
A1
(+) A2
23
33
24
34
M9985_c
A1
A2
(+)
AGND
AI1
AGND
AI1
AGND
(+)
0...10V
0...10V
AO0
AGND
(+)
AGND
M9987_b
Your Advantage
• Easy remote control of unit via mobile phone
• Easy configuration of unit via mobile phone
• SMS-status request of all i/p's - and o/p's via configurable shortcuts
• SMS text messages via customers SIM card
• Cyclic SMS message with configurable time interval (watchdog function)
Features
• According to directive 1999/5/EC (RTTE) for radio equipment and
telecommunications terminal equipment
• 4 digital inputs and 4 relay outputs
• Variant RP 5812/001 with 2 digital and 2 analogue inputs and
1 analogue - and 2 relay outputs
• Auxiliary voltage DC 24 V
• DC 24 V digital inputs
• Automatic SMS messages for status changes
• Quad-Band GSM-Module for 850, 900, 1800 and 1900 MHz
(GSM = Global System for Mobile)
• Pin protection of SIM card
• Caller password protection against unauthorised access
• User Dialogue language for: German, English or French
• Configurable authorization levels for up to 16 users
• Assignment of different I/O's to different users
• Automatic sending of SMS when digital inputs change state
I.e. come on or go off or both (on rising edge or falling edge)
• Automatic sending of SMS when analogue inputs
- exceed preset lower and upper limits or
- when signal is within the preset window
- and when the signal returns to good state
• Adjustable
- Hysteresis for analogue inputs
- Time delay for each input
- Repeat time for SMS-transmitting
- Time delay for output status after starting the unit
- Time delay for activation of the output
• SMS for device status to the system administrators
• SMS-counter to monitor the remaining account
• No interruption of operation after Voltage failure due to integrated
Li-Ion battery backup 24Hours
• Compact width: 70 mm
Approvals and Markings
Application
• Remote monitoring control and operation of
- Machinery and installations for industry and building automation.
- Small power plants
- Remote buildings
- Unmanned production plants
- Air-conditioning and refrigeration systems
- Heating systems
- Elevators and escalators
- Alarm systems, burglar alarms
- Smoke, fire and gas warning systems
- Doors, gates and windows
- Flood warning systems
• Level alarm in pumping stations
• Remote shut down of rental equipment when payment overdue
• Level monitoring in silos, tanks, etc.
1
22.02.13 en / 313

Advertisement

loading
Need help?

Need help?

Do you have a question about the INFOMASTER SMS RP 5812 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DOLD INFOMASTER SMS RP 5812

  • Page 1 Monitoring Technique INFOMASTER SMS SMS-Telecontrol Module RP 5812 Your Advantage • Easy remote control of unit via mobile phone • Easy configuration of unit via mobile phone • SMS-status request of all i/p’s - and o/p’s via configurable shortcuts • SMS text messages via customers SIM card •...
  • Page 2 Indication Settings green LED „U “: on when supply connected Set up procedure of SMS-Telecontrol module yellow LED „GSM“ • Wire the i/p’s- o/p’s and the auxiliary supply connections off: SMS-Telecontrol module is off • Press the SIM eject button (use pen tip), insert the SIM-card with the Preconfigured pin 1234 into the SMS-Telecontrol module flashes 600ms on / 600 ms off: SMS-Tele control module searches for •...
  • Page 3 Technial Data Standard Types Outputs RP 5812S DC 24 V Article number: 0065147 Contacts: • Auxiliary Voltage U DC 24 V RP 5812: 4 N/O contacts • Inputs: 4 digital inputs DC 24 V RP 5812/001: 2 N/O contacts • Outputs: 4 relay outputs N/O contacts Thermal current I •...
  • Page 4 LEDs for each I/O on the front of the unit indicate the status of the in- and outputs. E. DOLD & SÖHNE KG • D-78114 Furtwangen • PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356 e-mail: dold-relays@dold.com •...